| 03/05/2009 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T09CM00498 4145 East Sixth Street Detached garage & storage for SFR TRANSMITTAL: March 5, 2009 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO). This site is located in the R-1 Zone (LUC Section 2.3.4.2.A.1). The Development Designator is "G" (LUC Section 3.2.3.1.B) and the Perimeter Yard Indicator is AA (LUC Section 3.2.6.4). The DDO process and approval is required for the location of the proposed garage with a storage facility. The greater of six (6) feet or two-thirds (2/3) the wall height of the building facing an interior lot line is required. The wall height is measured from the ground to the highest point of the wall. The wall height of the proposed garage is ten (10) feet. The required setback is six (6) feet eight (8) inches. The proposed setback to the west property line is three (3) feet six (6) inches. |
| 03/05/2009 | MICHAEL ST. PAUL | NPPO | REVIEW | Passed | |
| 03/26/2009 | CAGUILA1 | ENGINEERING | REVIEW | Needs Review | |
| 03/26/2009 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Needs Review |