Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T09CM00482
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/10/2009 | GERRY KOZIOL | WWM | REVIEW | Denied | need plumbing drawings |
03/12/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET AE201; PARTITION G1/G2/G3 DETAILS: INDICATE IN THESE DETAILS HOW THE TOP AND BOTTOM OF THE PARTITION WALLS ARE CONNECTED TO THE STRUCTURE ABOVE AND BELOW TO RESIST LATERAL LOADS SPECIFIED IN THE 2006 IBC SECTION 1607.13. INCLUDE ALL BRACE MEMBER SIZES, CONNECTIONS OF THE BRACES (INCLUDING CONNECTOR SIZE AND QUANTITY) TO THE TOP OF THE PARTITION WALL AND TO THE STRUCTURE ABOVE, AND THE CONNECTOR SIZE AND QUANTITY FOR THE PARTITION WALL TO THE FLOOR STRUCTURE BELOW. |
03/12/2009 | ERIC NEWCOMB | ZONING HC SITE | REVIEW | Approved | |
03/17/2009 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | Project: T09CM00482 6245 E Broadway Bl , Office T I The electrical plans for this project have been denied for the following items, 1. There is no electrical circuitry drawn in for the lights, receptacles, or any other electrical equipment to be used. If new circuits are to be added include to which panels they are to be added to, the circuit numbers they will be assigned to, and load change to the panel. If they are existing and to be relocated please note on plan. Ray T Majuta Elect Plan Ck DSD City of Tucson 3-17-09 520-837-4988 |
04/01/2009 | ROBERT SHERRY | WATER | REVIEW | Approved | |
04/01/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Detail 4/AE201 shows an indirect waste receptor being installed inside of a cabinet. Revise the design to comply with the requirements of Section 804.1, UPC 2006. 2. Show how the new sink being installed in room 505 is to be plumbed (e.g. water and drain piping). Reference: Section 103.2.3, UPC 2006. |
04/01/2009 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | All of the diffusers and returns are being removed as part of the demolition in this suite and later reinstalled. Show how the replaced diffusers and returns are to be balanced so as to provide proper ventilation to the suite. Reference" Sections 106.3.1 and 403.3, IMC 2006. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
04/30/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
04/30/2009 | SUE REEVES | REJECT SHELF | Completed |