Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T09CM00441
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/20/2009 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: INO - Broadway and Kolb T09CM00441 Site Plan (2nd Review) TRANSMITTAL DATE: July 22, 2009 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC). Per D.S. 2-02.2.2.B. The proposed project encompasses five (5) parcels (133-22-500E, 133-22-500F, 133-22-500G, 133-22-500H, 133-22-4970), and it appears to be four (4) different owners. Parcel 133-22-4970 is a stand alone site and due to the expansion requires full code compliance for the entire parcel. The remaining parcels, 133-22-500E, 133-22-500F, 133-22-500G, 133-22-500H, act as one site. As a building area expansion calculation was not provided, but it appears that the proposed INO will not exceed a 25% expansion full code is required for the areas of work only. 2. This comment was not fully addressed. On sheet 1 of 7 show the property lines with dimensions and bearings for parcels 133-22-500E, 133-22-500F, & 133-22-500H. Sheets 2, 3, 4 & 5 should show the property lines with dimensions and bearings for parcel 133-22-500H. D.S. 2-02.2.1.A.5 Clearly show all property lines one the site plan along with dimensions and bearings. 3. This comment was not addressed. Zoning acknowledges that it was agreed that the information was not required for the existing buildings provide the height and dimension for the proposed building. D.S. 2-02.2.1.A.6 For all proposed and existing buildings and structures, provide the size, height, identify any overhangs, canopies. 4. D.S. 2-02.2.1.A.9 Show the required five (5) foot wide access aisle on the Class 2 bicycle parking detail, see D.S. 2-09.5.2 5. D.S. 2-02.2.1.A.9 There appears to be a proposed bollard that might interfere with the required 36" requirement between the rack and a perpendicular obstruction, see D.S. 2-09.5.1.B. If this bollard is to remain show it on the detail and provide a dimension. If the bollard is eliminated demonstrate how a parking vehicle will be prevented from encroaching into the bicycle parking area. 6. D.S. 2-02.2.1.A.10 Please clarify why sight visibility triangles (SVT's) are provided at the end of the drive-thru. 7. D.S. 2-02.2.1.A.10 Provide a far side SVT for the existing entrance/exit from the existing gas station to Kolb Road so that zoning can verify that the proposed monument sign does not encroach. 8. D.S. 2-02.2.1.A.11 Provide a width dimension for the parking area access lane (PAAL) located southeast of the proposed dumpster enclosure. 9. D.S. 2-02.2.1.A.11 Provide a width dimension for the PAAL connect the main shopping center to the existing gas station. 10. D.S. 2-02.2.1.A.12 At the end of the proposed PAAL that connects the main shopping center to the existing gas station either provide some type of barrier to prevent vehicles from crossing the property line or show how this connection will work on the plan. 11. Zoning acknowledges the photometric plan, show the site lighting on the site plan. D.S. 2-02.2.1.A.25 If applicable show all existing and proposed site lighting layout and type. 12. This comment was not fully addressed. Provide the required FAR, required vehicle parking, required and provided loading space and a building expansion calculation. D.S. 2-02.2.2. Provide calculations; Floor Area Ratio (FAR), Vehicle and Bicycle parking, Loading space, and Percent of Building Area Expansion, for parcel 133-22-4970 and separate from the remaining parcels 133-22-500E, 133-22-500F, 133-22-500G, 133-22-500H combined. For all calculations provide the required and provided. The building area expansion for parcels 133-22-500E, 133-22-500F, 133-22-500G, 133-22-500H maybe a negative percentage but is necessary as building area expansions are cumulatively and may effect future development. 13. D.S. 2-02.2.2.A.4 Zoning acknowledges that an agreement was made in regards to the provided number of vehicle parking spaces based on a provided vehicle parking space number on a previously approved site plan. Provide a copy of that site plan with the next submittal. 14. D.S. 2-02.2.2.A.4 The provided bicycle parking calculation shows 2 required and 2 provided. Based on the bicycle parking detail there are eight (8) bicycle parking spaces provided, please clarify 15. Depending on how the above comments are addressed addition comments may be forth coming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t09cm00441 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents. |
| 07/20/2009 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | 1. The ramp at the East end of the marked crossing shown on the site plan sheet 3 of 7, does not comply with ICC/ANSI 117.1, Section 306.7, no landing at the top of the ramp is provided as per detail 6/6. 2. The detectable warnings shown on the site plan and detail 10/6 do not comply with Section 406.12, 24" deep detectable warning. 3. Final approval can not be provided until results of DSMR (accessible route to all buildings) is provided. 4. Provide a "Van Accessible" sign on the sign detail, 1B/7. 5. At detail 10/6, please provide a reference note to Construction Notes on sheet 3. END OF REVIEW |
| 07/24/2009 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 08/05/2009 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Doug Couper DATE: August 11, 2009 920 Main Street, Suite 1150 Irvine, California, 92614 Subject: IN-N-OUT Burger, 7111 E. Broadway Blvd. Site plan T09CM00441 (Second Review) T14S, R15E, Section 08 RESUBMITTAL REQUIRED: Site Plan. The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. List the disturbance of both sites. Where is it shown on the Site Plan? 3. Show details of all drainage structures in the DR, including basins and weir details. Show details on how the stormwater discharges from the basins. 4. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. 5. Fully dimensioned loading space(s) and maneuvering area(s) for the refuse service vehicles per D.S. 2-02.2.1.14. 6. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. 7. Add to the Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. 8. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. The new trash and compact enclosure cannot be accessed by the service vehicle. The max. straight and clear back up distance of 50' for the service vehicle is required. Obtain permission of from environmental services for the location of the trash compactor, it does not meet D.S. listed above. Contact Andy Vera at 791-3785 or Andy.Vera@tucsonaz.gov 9. Call out the standard detail number for the refuse enclosure detail 2/7. Also the refuse enclosure requires side wall bollards for wall protection. Drainage Report: 1. The DR has been accepted conditionally on the following comment. 2. Show details of all drainage structures in the DR, including basins and weir details. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/7111 E. Broadway Blvd. 2 SITE |
| 08/10/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The waste piping shown on the detail utility sheet of the site plan (sheet 5 of 7) appears to indicate that all of the wastes from the building will flow through the gravity grease interceptor. Per Section 1014.3.2.2, UPC 2006, toilets and urinals may not drain through a gravity grease interceptor. 2. The presence of a private manhole in the building sewer will require a General Permit from the Pima County Department of Environmental Quality and a separate plumbing permit from the City of Tucson. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/10/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 09/10/2009 | SUE REEVES | REJECT SHELF | Completed |