Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T09CM00418
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/25/2009 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 02/25/2009 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide ventilation for the salon per Section 403.3, IMC 2006. 2. Provide a vent for the clothes dryer. |
| 02/25/2009 | ERIC NEWCOMB | ZONING HC SITE | REVIEW | Denied | 1. SEE BUILDING COMMENTS. |
| 02/25/2009 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 02/25/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEETA-2: INTERIOR WALL IS REQUIRED TO BE BRACED AT THE TOP TO RESIST LATERAL LOADS PER THE IBC SECTION 1607.13. INCLUDE IN THE DETAIL THE BRACING SIZE AND SPACING, THE CONNECTOR SIZE AND QUANTITY FOR THE BRACE TO THE STRUCTURE ABOVE AND TO THE TOP OF THE WALL, AND THE CONNECTION SIZE AND SPACING AT THE BOTTOM OF THE WALL. |
| 02/25/2009 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 02/25/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Provide a detail of the water heater installation, including the excess pressure relief, expansion tank, and valves. Reference: Sections 103.2.3, 605.5, 608.3, and 608.7 UPC 2006 |
| 02/25/2009 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 02/25/2009 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
| 03/02/2009 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 03/02/2009 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review | |
| 03/02/2009 | CAGUILA1 | ELECTRICAL-COMMERCIAL | REVIEW | Needs Review |