Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T09CM00283
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/19/2009 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | 1. West entrance ramp and landing: Comments on large scale details shown on Sheet A-2 a. Strike side of door on the outside must have 18" clearance as per ANSI 117.1, Section 404.2.3.1 (a). b. Contimue handrails to face of building wall. c. 5'-0" clearance is from inside face of handrail to inside face of handrail. 2. North entrance ramp and landing to Patio: a. Continue handrail around side and top of landing to patio edge. b. Provide handrail on both sides of ramp. c. Provide 5'-0" clearance from inside face of handrail to inside face of handrail at landing. |
| 05/22/2009 | PAUL MACHADO | ENGINEERING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/09/2009 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 06/09/2009 | SUE REEVES | REJECT SHELF | Completed |