Permit Review Detail
Review Status: Active
Review Details: COMMERCIAL TI
Permit Number - T09CM00251
Review Name: COMMERCIAL TI
Review Status: Active
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/03/2009 | RONALD BROWN | ADA | REVIEW | Passed | NOT A COT PROJECT |
02/03/2009 | GERRY KOZIOL | WWM | REVIEW | Passed | |
02/03/2009 | DAVE MANN | FIRE | REVIEW | Approved | |
02/04/2009 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
02/10/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. MINIMUM 3/32" LETTERING IS REQUIRED ON ALL DRAWINGS UNLESS A WRITTEN APPEAL IS APPROVED BY THE BUILDING OFFICIAL, JESSIE SANDERS. THIS APPROVED APPEAL MUST ACCOMPANY DRAWINGS SUBMITTED FOR CHECKING. 2. SHEET G-004: SINCE THE EXISTING RESTROOMS ARE NOT IN THIS CONTRACT, THE MAJORITY OF THE DETAILS ON THIS SHEET CAN BE REMOVED. 3. SHEET I-201 NOTES: THE PARTITION PLAN LEGEND INDICATES NEW PARTITION TYPE A2 U.N.O., WHILE THE GENERAL PARTITION NOTES INDICATE NEW PARTITIONS TO BE TYPE A3 U.N.O. CLARIFY. 4. SHEET I-201; PARTITION D: PROVIDE DETAIL FOR PONY WALL CONNECTION TO EXISTING WALL TO RESIST LOADS PER IBC SECTION 1607.13. 5. SHEET I-901; TYPE A PARTITION DETAIL: PROVIDE THE LOCATION OF THE DETAIL AT THE TOP OF THE WALL. THE DETAIL SHOULD INDICATE CONNECTION SIZE/QUANTITY/SPACING TO RESIST LOADS PER IBC SECTION 1607.13. |
02/10/2009 | ERIC NEWCOMB | ZONING HC SITE | REVIEW | Denied | 1. SEE BUILDING COMMENTS. |
02/24/2009 | ROBERT SHERRY | WATER | REVIEW | Approved | |
02/24/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
02/24/2009 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Detail 3/TH-3 shows the condensate from AC-1 being pumped to an existing gravity condensate drain. Show the size, location, and termination of the existing condensate drain along with the tonnage of the units currently connected to it. Reference: Section 307.2, IMC 2006. 2. Reprint the background for plan 1/TH-2 so it is legible. Reference: Section 106.3.1, IMC 2006. |
02/26/2009 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
02/27/2009 | SUE REEVES | REJECT SHELF | RECEIVED |