Review Status: Completed

Review Details: SITE

Permit Number - T09CM00231
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/30/2009 STEVE SHIELDS ZONING REVIEW Approved
02/02/2009 PETER MCLAUGHLIN NPPO REVIEW Approved
02/02/2009 PETER MCLAUGHLIN LANDSCAPE REVIEW Approved
02/02/2009 ERIC NEWCOMB ZONING HC SITE REVIEW Denied 1. CONFIRM EXISTING WALKWAY (ACCESSIBLE ROUTE) COMPLIANCE WITH ANSI 117.1, SECTIONS 403.3 SLOPES.
2. HOW DO YOU ACCESS FROM PARKING AISLE TO EXISTING ACCESSIBLE ROUTE, NEED A RAMP?
3. DRAW NEW ATTACHED ACCESSIBLE ROUTE 4' WIDE TO MATCH EXISTING ACCESSIBLE ROUTE
4. PROVIDE DETECTABLE WARNING AT BOTH ENDS OF MARKED CROSSING AS PER ANSI 117.1 SECTIONS 406.12 AND 406.14.
5. EXISTING ACCESSIBLE ROUTE NEXT TO BUILDING HAS A 6" CURB? CONFIRM AND PROVIDE A RAMP ACCORDINGLY. NOT ENOUGH SPACE FOR A RAMP IN FRONT OF DOORS. RELOCATE MARKED CROSSING AWAY FROM DOORS AND PROVIDE A SIDEWALK RAMP AS PER SECTION 405.
02/02/2009 LOREN MAKUS ENGINEERING REVIEW Approved
02/02/2009 ENEWCOM1 ADA REVIEW Passed NOT A COT PROJECT
02/02/2009 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
02/03/2009 MARTIN BROWN FIRE REVIEW Approved