Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T09CM00108
Parcel: 130152670

Address:
4601 E 27TH ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING-WALKTHRU

Permit Number - T09CM00108
Review Name: RESIDENTIAL BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2009 MICHAEL ST. PAUL ZONING REVIEW Approved
01/29/2009 BIANCA RAMIREZ ENGINEERING REVIEW Approved Shed to be built in a manner to prevent floatation, collapse, and lateral movement.
2. Shed must be used solely for storage, parking of vehicles, and/or building access.
3. No electrical is to service shed.
4. No machinery and equipment which service a building such as furnaces, air conditioners, heat pumps, hot water heaters, washers, dryers, elevator lift equipment, electrical junction and circuit breaker boxes, and food freezers are permitted.
5. Shed to have a minimum of two openings installed with a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided.
a. The bottom of all openings shall be no higher than one foot above grade.
b. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwaters.
6. Within 10 days after construction has been completed, the applicant must contact the District to verify all the requirements have been met. Please call (928) 771-3197 for final inspection.
01/29/2009 MICHAEL ST. PAUL NPPO REVIEW Passed
01/29/2009 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Passed