Review Date Reviewer's Name Type of Review Description Status Comments
12/04/2009 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SIGN FACE ELEVATION: INDICATE THE DIRECTION OF THE FACE BEING DEPICTED.
2. SIGN FACE ELEVATION: LOCATE ALL 3"X6" STRINGERS.
3. SIGN FACE ELEVATION AND SCOPE OF WORK (BULLET 4): PROVIDE QUANTITY AND DIMENSIONS OF WOOD SECTIONS BEING REPLACED AND INSTALLED.
4. GENERAL: CLARIFY ALL ABBREVIATED REFERENCES.
5. SIGN FACE ELEVATION: PROVIDE THE FINISHED LENGTH OF THE APRON.
6. SCOPE OF WORK (BULLET 3): PROVIDE QUANTITY AND DIMENSIONS OF REPLACEMENT APRON SECTIONS AND LENGTH OF APRON SUPPORT STRINGERS.
7. TYPICAL SECTION: PROVIDE STRINGER ELEVATIONS.
8. STRINGER BETWEEN UPRIGHTS: PROVIDE DIMENSIONAL DETAIL OF THE Z CLIPS, INCLUDING HEIGHT, WIDTH, LENGTH, AND THICKNESS.
9. GENERAL: PROVIDE A DESCRIPTION OF THE EXISTING LIGHT FIXTURES AND LAMPS TO BE REMOVED AND REINSTALLED. EXISTING FIXTURES ARE TO REMAIN ON THE SITE WITH NO OTHER FIXTURES (NEW OR USED) TO BE INSTALLED.
10. GENERAL: PROVIDE TYPICAL DETAILS FOR LIGHT FIXTURE MOUNTING BRACKETS AND FOR SUPPORTING RIGID CONDUITS AT THE TOP OF THE BILLBOARD.
11. GENERAL: PROVIDE A NOTE STATING THAT NO PARTS OR COMPONENTS ARE TO BE REMOVED, INSTALLED, REPLACED, OR REINSTALLED EXCEPT AS NOTED ON THE PLANS.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/30/2009 DELMA ROBEY OUT TO CUSTOMER Completed