| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/16/2009 | ANDREW CONNOR | NPPO | REVIEW | Approv-Cond | Ensure that all Engineering comments and concerns are addressed prior to landscape / NPPO approval stamp. |
| 11/19/2009 | MATT FLICK | ENGINEERING | REVIEW | Denied | The grading plan is not acceptable for approval. The following comments are offered: 1. Add the activity number (T09OT02333) for the floodplain permit to the cover sheet. 2. Add the activity number (T09BU01633) for the grading permit to all sheets. 3. Submittal of a SWPPP and ADEQ authorization is required. The grading plan will not be approved prior to review of the SWPPP and submittal of the authorization. 4. Sheet 2: Suggest indicating on Cross-Section B-B that the sediment trap is to be level. It is acknowledged that the grades shown on Sheet 3/5 indicate a level grade. 5. Sheet 4: (SE TRASH ENCLOSURE) Plan view indicates riprap slope; cross-section shows a vertical wall. Please clarify. 6. Sheet 4: (SE TRASH ENCLOSURE) Indicate if vertical basin wall is to be constructed by others or per this plan (didn't see sufficient detailing on this plan - assume it's by others and contained on another plan). General: On items to be constructed by others or per another plan set, please indicate which plan set is to be used. In particular, there are channel walls, screen walls used as channel walls, and trash enclosure walls used as channel walls that have insufficient detailing to be constructed from this plan set. Matt Flick, P.E. Planning & Development Services City of Tucson Phone: (520) 837-4931 Fax: (520) 791-4340 Please visit our web site: www.tucsonaz.gov/dsd The drainage report and geotechnical engineering report are acceptable for grading plan approval. SUBMITTAL REQUIRED: SWPPP RESUBMITTAL REQUIRED: Grading Plan |
| 12/01/2009 | DAVID RIVERA | ZONING | REVIEW | Denied | While the grading plan and matches the approved development plan zoning cannot approve the plan until the comments by engineering are addressed. Revise the dollar amount for the fine labeled on the reserved parking sign to $532. Zoning is willing to review and approve the gradintg plan over the counter once the engineering reviewer approves the plan. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/09/2009 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |