Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T09BU01577
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/15/2009 | ANDREW CONNOR | NPPO | REVIEW | Approv-Cond | Ensure that all Engineering comments and concerns are addressed prior to Landscape/NPP approval stamp. |
| 12/17/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: December 17, 2009 SUBJECT: 3 Single Family Residences TO: SEPASSI REZA & MALEKNIAZI NAHID CP/RS 5216 N STANDING ROCK PL TUCSON AZ 85750-7029 TO: a.s.i architects studio inc. LOCATION: 1447 E Blacklidge Drive, T13S, R14E, Section 31, Ward 3 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T09CM02827 (Second Review) RESUBMITTAL REQUIRED: Site Plan, Grading Plan and Drainage Report SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Please include a response letter to the comments along with the corrected copies of the Site Plan, Grading Plan and Drainage Report. Site Plan: 1. The most recent aerial photo of the building does not match what is depicted on the site plan. Please modify site plan to represent actual footprint of existing buildings and/or clarify. Show existing buildings on site plan. Add note in regards to whether or not the existing buildings are to remain or to be demolished. Add activity number to site plan of any demolition permits. Response: Provide activity number for demolition referenced in 2008 on the plans. 2. Complied 3. Complied 4. Complied 5. Complied 6. Complied 7. Complied 8. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15. Response: There is floodplain that should be identified along Blacklidge Dr. 9. Complied 10. Complied 11. Complied 12. Complied 13. Verify that all easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. Response: Standard note to remain until plans are approved. Acknowledge that there are no easements on parcel. 14. Provide City Field Book and page number for benchmark per D.S. 2-02.2.1.23. Provide contour interval on plan, preferably with north arrow and scale. 15. Verify that all fences, walls, or vegetation for screening and sight visibility have been indicated by type, material, height, location and spacing per D.S. 2-02.2.1.27. Response: Show 2' setback between wall and property line. 16. Show site plan and grading plan number in the lower right hand corner of each sheet accordingly per D.S. 2-02.2.1.29. Response: Show the site plan number and grading plan number on all sheets. 17. DS Sec.2-02.2.1.A.32: the detail with dimensions for refuse container on the site plan indicated that there will be curbside pick up. Enclosures are required to have a minimum inside clear dimension of 10 feet by 10 feet between steel bollards that are required between the container and the enclosure's rear and sidewalk. Refer to DS Sec.6-01.4.2 for specifications and requirements on access, placement of containers, bin enclosure and construction. For curbside pickup a letter of approval will be required from COT Environmental Services and a Development Standard Modification Request (DSMR) may be required prior to site plan approval. Response: Comments to remain. DSMR(s) required. 18. DS Sec.2-02.2.1.A.32: Label and show the maneuverability for refuse vehicles in plan view at the proposed refuse container location. Current positioning of trash area does not allow for 14' X 40' clear approach, show access dimensioning to proposed trash enclosure. Response: Comments to remain. DSMR(s) required. 19. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please indicate off site elevation within 100' of property line. Response: Show offsite elevations within 100' of property lines. 20. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. Response: Standard comment is to remain until plans are approved. 21. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice. Response: Show roof drainage along with flow arrows. 22. Complied 23. Complied 24. Complied 25. Complied 26. Please clarify the purpose of site plan key note 9. Response: Clarify on site plan or in key note 9. 27. Complied 28. Call out peak discharges entering and exiting the site. Response: Provided Q100(s) are not representative of information provided in drainage report. 29. Complied 30. Black markings within identified curb should be called out. Are these depressed curbs? Response: Unable to locate note identifying depressed curb. 31. Provide proof that water will continue north onto public street north of northern adjacent parcel. Must show that there is no adverse impact. Response: The drainage report indicated 5.31 cfs for developed conditions. The report appears to be the old version with old design exiting onto west property. Please revise and update accordingly. 32. Additional comments may be forthcoming. Drainage Report: **Schedule meeting with Engineer and Architect and City of Tucson staff. ** 1. Backwater analysis shows elevations in the range of 2707 and site/grading plans indicate 70 elevations. Please review and revise accordingly. 2. Provide floodplain limits and water surface elevations from drainage report on site/grading plan. 3. Drainage Report is not reflective of site plan and grading plan. 4. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
| 12/18/2009 | DAVID RIVERA | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: David Rivera Principal Planner PROJECT: T09BU01577 1447 E Blacklidge Drive Grading Plan Review Residential Triplex Development - Multi Family Residential Use TRANSMITTAL DATE: December 18, 2009 COMMENTS: 1. Zoning has reviewed the grading plan for compliance with the site plan. While the grading plan appears to be in compliance with the unapproved site plan zoning cannot approve the plan until all PDSD reviewers have approved the site plan. 2. While the grading plan matches the current version of the unapproved site plan sheets as it pertains to zoning requirements the grading plans cannot be approved due to possible design changes based on review comments by the remaining PDSD review agencies. If the applicant wishes to have the grading plan reviewed over the counter as part of a walk-through review please call in advance and set up an appointment. Contact Steve Shields or David Rivera for over the counter review. 2. Zoning is willing to review the grading plan over the counter with an appointment on a walk-through basis assuming the approved and stamped site plan is available for review and included with the grading plan package. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised grading plans. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/09/2010 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 02/09/2010 | SUE REEVES | REJECT SHELF | Completed |