Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T09BU01577
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/27/2009 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Reza Homes T09BU01577 Grading Plan (1st Review) TRANSMITTAL DATE: October 27, 2009 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C:\planning\grading\t09bu01577 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Approved site plans and additional requested documents |
| 10/28/2009 | ANDREW CONNOR | NPPO | REVIEW | Denied | Ensure that all Engineering comments and concerns are addressed prior to Landscape / NPP approval. |
| 11/18/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: November 19, 2009 SUBJECT: 3 Single Family Residences TO: a.s.i architects studio inc. LOCATION: 1447 E Blacklidge Drive, T13S, R14E, Section 31, Ward 3 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T09CM02827 (First Review) RESUBMITTAL REQUIRED: Site Plan, Grading Plan and Drainage Report SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Please include a response letter to the comments along with the corrected copies of the Site Plan, Grading Plan and Drainage Report. Site Plan: 1. The most recent aerial photo of the building does not match what is depicted on the site plan. Please modify site plan to represent actual footprint of existing buildings and/or clarify. Show existing buildings on site plan. Add note in regards to whether or not the existing buildings are to remain or to be demolished. Add activity number to site plan of any demolition permits. 2. Please label lot dimensions to accompany bearings along south property line per D.S. 2-02.2.1.5 3. Provide all existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use per D.S. 2-02.2.1.6. 4. DS Sec.2-02.2.1.A.11: Revise the site plan to show the minimum 12-foot separation that is required between adjacent driveways. Show and label the existing driveways adjacent to the site and verify the 12-foot minimum width. Refer to Tucson Code (TC) Chapter 25-39 for curb cut and driveway requirements. 5. DS Sec.2-08.4.1.c: A sidewalk will be provided adjacent to any parking space accessed by a PAAL where the space is located on the same side of the PAAL as any building and no other parking spaces or PAALs intervene. Provide 4' sidewalk - dimensions and label appropriately. 6. D.S. 2-02.2.1.A.12 Provide a backup spur along the north end of the proposed PAAL for maneuverability from parking spaces per D.S. 3-05.2.2.D. 7. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. 8. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15. 9. Please list estimated cut & fill quantities on the site plan per D.S. 2-02.2.1.17. 10. Label dimensioned right-of-way and indicate whether dimension is existing or future. If existing and future right of way are the same please indicate on plans per D.S. 2-02.2.1.19. 11. DS Sec. 2-05.2.4.H.2: Provide the right-of-way (ROW) recordation information for Blacklidge Drive (I-660). 12. DS Sec.2-02.2.1.A.19: Dimension the sidewalk along Blacklidge Drive. 13. Verify that all easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 14. Provide City Field Book and page number for benchmark per D.S. 2-02.2.1.23. Provide contour interval on plan, preferably with north arrow and scale. 15. Verify that all fences, walls, or vegetation for screening and sight visibility have been indicated by type, material, height, location and spacing per D.S. 2-02.2.1.27. 16. Show site plan and grading plan number in the lower right hand corner of each sheet accordingly per D.S. 2-02.2.1.29. 17. DS Sec.2-02.2.1.A.32: the detail with dimensions for refuse container on the site plan indicated that there will be curbside pick up. Enclosures are required to have a minimum inside clear dimension of 10 feet by 10 feet between steel bollards that are required between the container and the enclosure's rear and sidewalk. Refer to DS Sec.6-01.4.2 for specifications and requirements on access, placement of containers, bin enclosure and construction. For curbside pickup a letter of approval will be required from COT Environmental Services and a Development Standard Modification Request (DSMR) may be required prior to site plan approval. 18. DS Sec.2-02.2.1.A.32: Label and show the maneuverability for refuse vehicles in plan view at the proposed refuse container location. Current positioning of trash area does not allow for 14' X 40' clear approach, show access dimensioning to proposed trash enclosure. 19. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please indicate off site elevation within 100' of property line. 20. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 21. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice. 22. List the consulting drainage engineer on the plans with the pertinent information. 23. Revise site plan key note to read: "Depress all landscaped areas 6" maximum for water harvesting". 24. North parking space adjacent to 3'4" wall, parking space is required to be 10'. 25. Provide standard detail number for site plan key note 11. 26. Please clarify the purpose of site plan key note 9. 27. Please provide dimension of sidewalk in site plan key note 20. 28. Call out peak discharges entering and exiting the site. 29. Check with ADA, Ronald Brown to verify that no handicap access ramps are required along Blacklidge. If they are required, revise accordingly. 30. Black markings within identified curb should be called out. Are these depressed curbs? 31. Provide proof that water will continue north onto public street north of northern adjacent parcel. Must show that there is no adverse impact. 32. Additional comments may be forthcoming. Drainage Report: 1. Backwater analysis shows elevations in the range of 2707 and site/grading plans indicate 70 elevations. Please review and revise accordingly. 2. Provide floodplain limits and water surface elevations from drainage report on site/grading plan. 3. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/20/2009 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 11/20/2009 | SUE REEVES | REJECT SHELF | Completed |