Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: WALLS SUBMITTAL
Permit Number - T09BU01405
Review Name: WALLS SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/14/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 10/16/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: October 16, 2009 SUBJECT: Wall TO: Star Consulting LOCATION: 930 W Glenn St, T13S R13 Sec35, Ward 3 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: Building Plan T09BU01405 (1st Review); Floodplain Use Permit T09OT02010 (1st Review). RESUBMITTAL REQUIRED: Building Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed building plan for the above referenced property. Engineering Division does not recommend approval of the building plan at this time. The following items need to be addressed to the next submittal: Please include a response letter to the comments along with the corrected copies of the site plan. BUILDING PLAN: 1. Building plan and Drainage Report Datum appear to be different. Please revise so that Building Plan and Drainage report elevations are on the same datum. 2. Provide water surface elevations for wall detail(s) A - Wall opening detail and B - Wall spacing detail. 3. Check drawing to ensure that elevations for topography are shown on site plan. 4. Revise plan to show 2' setback from property line for proposed wall. 5. Additional comments may be forthcoming. DRAINAGE REPORT: 1. Verify that site plan and topo on site plan are on the same datum. 2. Additional comments may be forthcoming. If you have any questions, I can be reached at 520-837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 |
| 10/16/2009 | TERRY STEVENS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Terry Stevens Lead Planner PROJECT: T09BU01405 930 W. Glenn 6' Block Walls TRANSMITTAL DATE: 10-16-09 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Along the north property line the wall is indicated as being built over an easement. Provide written documentation granting approval for building over the easement from all affected utility companies. 2. This property is currently in review for a rezoning of a portion of the property. Zoning strongly suggests that you contact Michael Wyneken with Rezoning to verify any possible rezoning conditions that may affect the type, style, height, location or configuration of the proposed wall. 3. At the time of submittal it was noted to see letter from C. Gross. Pleas provide a copy of the letter for review purposes. If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961 C:\planning\cdrc\DSD\T09BU01405.doc |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/03/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 11/03/2009 | SUE REEVES | REJECT SHELF | Completed |