Permit Number: T09BU00580
Parcel: 116275790

Review Status: Completed

Review Details: RESUBMITTAL - GRADING ALL

Permit Number - T09BU00580
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/09/2010 ELEIBOL1 ENGINEERING REVIEW Approved DATE: September 9, 2010
TO: Timothy Robertson, RA
SUBJECT: 977 S Bill Martin Dr Site/Grading Plan Review 3rd Resubmittal
LOCATION: Canyon View at Starr Pass lot 28
REVIEWER: Elizabeth Leibold PE
ACTIVITY NUMBERS: T09CM00922 / T09BU00580

Summary: Engineering Division has reviewed the submitted plan review package over the counter in 2 reviews this week, including a copy of the revised grading plan. Engineering recommends approval with the following conditions to be completed during grading construction.

GRADING PERMIT CONDITIONS:
The following conditions apply to grading permit T09BU00580:
1) Call for Pre-construction meeting. Discuss during Pre-con or contact PDSD Engineering Inspector to confirm which grading inspections may be needed. For a PDSD Engineering Inspection, call IVR (740-6970), or schedule with a Customer Service Representative at Planning & Development Services Department (PDSD), or contact PDSD Engineering at 837-4888, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html
2) Separate building permit applications / reviews are required for any walls.
3) Temporary erosion/sediment control shall be located within grading limits.
4) Construction staging areas, construction materials, and vehicle parking shall be located within grading limits.
5) Exceeding grading limit disturbance may result in Stop Work Order or require re-submittal of grading plans for re-review.
6) A geotechnical addenda will be required if constructed slopes exceed 2:1(H:V) for fill or 1:1(H:V) for cut.
7) Per HDZ requirements, all rip rapped slopes shall have handplaced stone with filter fabric or handplaced grouted stone.
8) A copy of stamped approved grading plans, permits, and reports shall be kept at site at all times, until final grading approval.
9) As-builts are required to be submitted under activity number T09BU00580 to PDSD permit clerks. They will be reviewed and then if acceptable, a copy will be provided to PDSD Engineering Inspector for final grading inspections. For Permit Project Closure documentation, submit: 2 copies of as-built final revised grading plans and any applicable geotechnical addenda.

I can be reached at 837-4934 if you have questions.

Elizabeth Leibold, PE
Civil Engineer
Engineering Division
Planning & Development Services Department
09/09/2010 ELEIBOL1 ZONING REVIEW Denied per MSP
09/10/2010 ANDREW CONNOR NPPO REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
02/02/2011 SUE REEVES OUT TO CUSTOMER Completed