Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T09BU00475
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/08/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: April 10, 2009 SUBJECT: Grading TO: ESP Group / Jeff Stine LOCATION: 202 E Speedway Boulevard, T14S, R13E, Section 12, Ward 6 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T09BU01458 (First Review) RESUBMITTAL REQUIRED: Grading Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed grading plan for the above referenced property. Engineering Division does not recommend approval of the grading plan at this time. Please address the following review comments prior to the next submittal. Grading Plan: 1. Add the following notes to the grading plan notes: " "The approved Grading Plan is the only acceptable construction plan onsite. The Contractor may not use any other plans, such as the approved Tentative Plat and/or Development Plan, for construction purposes. The Contractor may ask the Development Services Inspector to consult with the other approved plans for additional information or details that might not be included on the approved grading plan but needed for completion of work." 2. List subdivision or Development number. 3. Verify accurate area of disturbance. 4. Show Phase numbers and delineate. Each phase must function independent of future phases. 5. Show cross section with transverse and longitudinal slopes. 6. Call out scupper type and reference appropriate City of Tucson detail or provide detail on grading plan on grading plan. 7. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 8. Flow arrows, grades and drainage scheme indicate that the flow is draining away from landscaping areas and curb openings. Revise drainage of parking lot to drain into landscaping areas. 9. Identify exiting and new pavement areas. It appears that PAAL identified within grading limits will be replaced with new pavement. However, it is not called out. Please clearly indicate on grading plan. 10. Call out the grading plan activity number in the lower right hand corner of each sheet. 11. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca Ramirez, CFM Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 (520) 879-8010 fax |
| 04/10/2009 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | April 10, 2009 Development Services Department Zoning Review Section Michael St.Paul Planning Technician T09BU00475 Grading Plans for T08CM03258 Address: 202 East Speedway Blvd. Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. We cannot verify that the grading plan is in compliance with an approved site plan for this site. Please provide one copy of the stamped approved site plan with your next submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved site plan. Additional comments may be forthcoming. |
| 04/16/2009 | ANDREW CONNOR | NPPO | REVIEW | Approv-Cond |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/22/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 04/22/2009 | SUE REEVES | REJECT SHELF | Completed |