Permit Review Detail
Review Status: Completed
Review Details: REVISION - GRADING
Permit Number - T09BU00263
Review Name: REVISION - GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/06/2010 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: April 6, 2010 SUBJECT: Grading TO: LOCATION: 3103 E Adams Street, T14S, R14E, Section 4 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T09BU00263 RESUBMITTAL REQUIRED: Grading Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed grading plan for the above referenced property. Engineering Division does not recommend approval of the grading plan at this time. Please address the following review comments prior to the next submittal. Please include a response letter to the comments along with the corrected copies of the grading plan. Please provide a drainage report with the next submittal. Grading Plan Comments: 1. DSMR will be required for sidewalks that are not meeting minimum width requirements. Revise detail to add 6 inch curb in detail. 2. New wall has been added to plan, provide scuppers and indicate positive drainage. 3. Original plan indicated new sidewalk being installed along Lee Street, north of future building C.4. 4. Provide all internal drainages shown; per site visit by David Roberts, Construction Inspection Supervisor, drainage is not constructed as indicated on plans. Additional site visit will be required prior to final approval. 5. South of new play area Top of Curb elevations are indicated on plans, however, inspector has indicated that no curb actually exists in this location, please revise accordingly. 6. Previous plans reference sidewalks to detail 3. New plan is referencing keynote 2, of which does not indicate width of sidewalk. 7. Western sidewalk along future building C.4, sidewalk is 42" and with building kickout is measuring out at 38" clear space, DSMR will be required for proposed sidewalk width. 8. Additional comments may be forthcoming. If you have any questions, I can be reached at Bianca.ramirez@tucsonaz.gov or 837-4928. Bianca Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
| 04/07/2010 | ANDREW CONNOR | NPPO | REVIEW | Denied | Ensure that all Engineering comments and concerns are addressed prior to NPP / Landscape approval. |
| 04/08/2010 | ANDREW CONNOR | ZONING | REVIEW | Denied | April, 8 2010 Development Services Department Zoning Review Section Andrew Connor Planning Technician T09BU00263 Comments: The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved until all Engineering comments or concerns have been addressed. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/23/2010 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 04/23/2010 | SUE REEVES | REJECT SHELF | Completed |