Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T09BU00173
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/09/2009 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | April 10, 2009 Development Services Department Zoning Review Section Michael St.Paul Planning Technician T09BU00173 Grading Plans for D08-0053 Address: 284 South Williams Blvd. Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. The grading plans submitted do not match the approved development plan. Please revise the development plan to include the CMU enclosure you state is required by Tucson Water. Please submit one copy of the approved and stamped Development Plan, Landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved development plan. Additional comments may be forthcoming. |
| 04/10/2009 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: April 10, 2009 SUBJECT: Towne Place Suites Hotel- 2nd Grading Plan Review TO: Greg Carlson Engineering. LLC LOCATION: 384 S Williams Blvd, T145S R14E Sec14 Ward 6 REVIEWERS: Jason Green, CFM ACTIVITY: T09BU00173 (Grading Plan) SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised grading plan (T09BU00173), Drainage Report (Greg Carlson Engineering, LLC, 16JAN09) and Stormwater Pollution Prevention Plan (Greg Carlson Engineering, LLC, 04FEB09, revised 31MAR09) for the above referenced property. Engineering Division recommends approval of the grading plan application at this time. GRADING PLAN COMMENTS: 1) Complied. 2) Complied. 3) Complied. 4) Complied. 5) Complied. 6) Complied. 7) Complied. 8) Complied. 9) Acknowledged. 10) Acknowledged. STORMWATER POLLUTION PREVENTION PLAN: 11) Complied. 12) Complied. GENERAL COMMENTS: Call for a Pre-construction meeting prior to start of earthwork. To schedule a DSD Pre-construction meeting, SWPPP inspection or general Engineering Inspections, call IVR (740-6970), or schedule with a Customer Service Representative at the Development Services Department, or contact DSD Engineering at 791-5550 extension 2101, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html For questions or to schedule appointments call me at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division COT Development Services |
| 04/10/2009 | JASON GREEN | ENGINEERING | REVIEW | Approved | Any changes required by other departments due to the new enclosure proposed around the water meter will require a re-review by DSD Engineering and a restamp of the grading plan. |
| 04/13/2009 | ANDREW CONNOR | NPPO | REVIEW | Denied | 1.The grading plans submitted do not match the approved development plan. A revised development plan will be necessary according to the DSD Grading Revision Policy dated 04/09/2009 2. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress; Enclosure can not be located within required landscape borders 3. Screens may extend a maximum of three (3) feet into the street landscape border. Revise location of Water Enclosure. 4. Include the revised and approved Development Plan with re-submittal 5. Additional comments may apply. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/17/2009 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 04/17/2009 | SUE REEVES | REJECT SHELF | Completed |