Permit Review Detail
Review Status: Completed
Review Details: LUCAPPS - OVERLAY ZONE REV
Permit Number - T08SA00089
Review Name: LUCAPPS - OVERLAY ZONE REV
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/19/2008 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 04/03/2008 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Steve Shields, Lead Planner PROJECT: T08SA00089 StarrPass Vistas Village II Hillside Development Overlay Zone TRANSMITTAL DATE: April 3, 2008 DUE DATE: April 07, 2008 COMMENTS: 1. This submittal was reviewed for compliance with the Land Use Code, specifically the Hillside Development Overlay Zone, Section 2.8.1. 2. The Zoning Review Section conditionally approves the overlay zone subject to the following conditions. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised tentative plat to verify that those changes do not affect any zoning requirements. 3. Please place the special application overlay case number T08SA00089 near the title block of all pages tentative plat and revise general note 28. 4. Zoning is not able to approve the overlay until approved by Engineering. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 I:\planning\cdrc\overlay\T08SA00089.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised tentative plat. |
| 05/20/2008 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approved | TO: Patricia Gehlen; CDRC Coordinator Consultant: RICK Engineering SUBJECT: Starr Pass Vistas Village 2 Tentative Plat Engineering 2nd Resubmittal Review REVIEWER: Elizabeth Eberbach LOCATION: T14S R13E Section 16 ACTIVITY NUMBERS: S07-033, T08SA00089 SUMMARY: The revised Tentative Plat sheets, revised Drainage Report, boundary closure calculation paperwork, schedules of title report, lot 17 concept plan, response letters, geotechnical engineering report with addenda, and HDZ application and ACS calculation were received by Engineering for review. The Drainage Report was reviewed for Tentative Plat purposes only. Engineering recommends approval of HDZ and ERZ Overlays for Starr Pass Village 2. Engineering recommends conditional approval of the Tentative Plat. CONDITIONS OF APPROVAL: 1) DS Sec.2-03.2.4.L.2: Some FFE's are shown too low; check minimum proposed finished floor elevations for lots 3, 7, 8, 10, 14, 15, 16, 17, 23, 24, 42, and 43 to assure they meet minimum FFE floodplain requirements adjacent to washes. Check/revise exhibit Figure 5 minimum FFE Required table to assure the correct WSEL is used to determine min FFE's. 2) DS Sec.11-01: For detail B/5, since this is a custom graded lot subdivision the word "minimum" should be used to clarify that the houses are not set at 6 feet but may not go closer than 6 feet from property line. 3) Provide hatching for Natural Open Space in legend on first sheet of Tentative Plat. 4) LUC Sec.2.8.1: Update General Note 28. 5) Check/correct the percent disturbance area on sheet 1 of ERR Report-plan. OTHER CONSIDERATIONS: 6) A final Drainage Report in CD form will be required to be submitted at Grading Plan or Final Plat review stage for archiving. Drainage response letters shall be added to the verbiage in the drainage report or added as a registrant's sealed letter. Per AzBTR, the registrant shall mark the CD copy of the professional document: "Electronic copy of final document; sealed original document is with (identify the registrant's name and registration number) 7) For Final Plat, boundary data will need to match title report exhibit, and bearings and distances shall be clarified as recorded, measured or calculated. 8) Contact Fire Department regarding application for fire box for proposed gate. An application will be enclosed with the grading plan package. Address conditions 1-5 for Tentative Plat resubmittal. Submit revised Tentative Plat, a bound copy of the geotechnical report with any addenda, revised Drainage Report, revised ERR plans, and response letter. Prior to resubmittal, you may schedule a meeting with me to go over your conditions. If you have any questions, please call me at 837-4934. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 05/21/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES May 21, 2008 Mirela Hromatka Rick Engineering, Inc. 1745 East River Road, Suite 101 Tucson, Arizona 85718 Subject: T08SA00089 Hillside Development Overlay Zone for Starr Pass Vistas Village II (S07-033) Dear Ken: Your submittal of March 10, 2008 for the above project has been reviewed by the Community Design Review Committee and CONDITIONALLY APPROVED. The conditions of approval are as follows: 1) closure of the public comment period, 2) approval by the DSD Director, and 3) the on-line comments being addressed on the developement plan prior to approval. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-6956 |