Plan Review Detail
Review Status: Completed
Review Details: PIA RESUBMITTAL
Plan Number - T08PI00017
Review Name: PIA RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/03/2008 | SMONTIE1 | UTILITY CLEARANCES | COT STREETS DIVISION | Completed | Please submit utility clearance letter for Qwest Communications. |
| 06/03/2008 | SMONTIE1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Completed | Please submit utility clearance letter for Qwest Communications. |
| 06/03/2008 | SMONTIE1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Completed | Please submit utility clearance letter for Qwest Communications. |
| 06/03/2008 | SMONTIE1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | Please submit utility clearance letter for Qwest Communications. |
| 06/03/2008 | SMONTIE1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Completed | Please submit utility clearance letter for Qwest Communications. |
| 06/03/2008 | SMONTIE1 | UTILITY CLEARANCES | COX COMMUNICATION | Completed | Please submit utility clearance letter for Qwest Communications. |
| 06/03/2008 | SMONTIE1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Completed | Please submit utility clearance letter for Qwest Communications. |
| 06/03/2008 | SMONTIE1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Passed | Please submit utility clearance letter for Qwest Communications. |
| 06/03/2008 | SMONTIE1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Passed | Please submit utility clearance letter for Qwest Communications. |
| 06/09/2008 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approv-Cond | Note #25. Pleae change the last name of Gary Witmoore to Wittwer, and add the (791-5100) phone number. |
| 06/19/2008 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approved | |
| 06/20/2008 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | June 20, 2008 SUBJECT: Irvington Road Right Turn Lane & Median Modifications, PIA T08PI0017, I-2008-019 PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal. 1. All curb access ramps along the development's frontage will have to be brought into compliance with current PC/COT Standards and Specifications and ADA requirements. 2. All existing 4' wide sidewalk along the development's frontage will have to be replaced with 6' wide sidewalk. 3. 6' wide sidewalk will have to be provided up to the junction of the Santa Cruz River Park multi-use path with a minimum 1' clearance provided between the sidewalk and any structure. A possibility may be to meander the sidewalk around the existing structures or relocate existing park facilities. Pima County Parks and Recreation will have to approve any modifications to the existing park facilities. 4. Provide the stationing and offsets for the relocated guard railing at the eastern end of the project. Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsoz.gov |
| 07/01/2008 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approved | |
| 07/07/2008 | SMONTIE1 | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
| 07/07/2008 | SMONTIE1 | PIA COORDINATOR | OUT TO CUSTOMER | Completed |