Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: PIA SUBMITTAL
Plan Number - T08PI00017
Review Name: PIA SUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/14/2008 | SMONTIE1 | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | Please submit utility clearance letters. |
04/14/2008 | SMONTIE1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | Please submit utility clearance letters. |
04/14/2008 | SMONTIE1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | Please submit utility clearance letters. |
04/14/2008 | SMONTIE1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | Please submit utility clearance letters. |
04/14/2008 | SMONTIE1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | Please submit utility clearance letters. |
04/14/2008 | SMONTIE1 | UTILITY CLEARANCES | COX COMMUNICATION | Denied | Please submit utility clearance letters. |
04/14/2008 | SMONTIE1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | Please submit utility clearance letters. |
04/14/2008 | SMONTIE1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | Please submit utility clearance letters. |
04/14/2008 | SMONTIE1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | Please submit utility clearance letters. |
04/21/2008 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | 1. TDOT has existing landscape and irrigation on the north side of Irvington in the location of the new paving and sidewalk. Please contact Streets to meet on site to review existing facilities. Irrigation lines will need to be addressed as well as the transplanting of existing trees. 2. The proposed hardscape on the median island on Irvington shall match the existing hardscape to the west. I believe that it is brick pavers. |
05/06/2008 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | April 29, 2008 SUBJECT: Irvington Road Right Turn Lane & Median Modifications, PIA T08PI0017, I-2008-019 PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal. 1. Include the plan number “I-2008-019” in title block of each sheet. 2. Include Development Services Department PIA activity number “T08000017” on cover sheet. 3. Provide a profile view for the proposed deceleration lane. 4. Indicate the placement of bituminous joint filler between the curb and concrete surface treatment of the proposed median island. 5. The existing curb access ramp on the west side of the driveway will have to replaced to accommodate the onsite pedestrian circulation path. Additionally, the access ramp must aligned with the opposing ramp. 6. Provide a detail of the area where the proposed sidewalk will join into the existing multi-use path. Show all existing structures. 7. Will the existing guardrail between stations +/- 296+00 and 296+50 have to be relocated? Show all existing structures within the construction prism. Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsoz.gov |
05/07/2008 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | We have reviewed this plan and have the following comments: 1. The City has irrigation and vegetation in this area. This vegetaion will need to be relocated and irragation lines will need to be sleeved. Please contact Paul Rosenboom at 791-3154 ext 234 for information and assistance. A photo of the area has been sent back with the redlined plans. This photo shows conflict areas. |
05/14/2008 | SMONTIE1 | PIA COORDINATOR | CUSTOMER CALLED | Completed | |
05/14/2008 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Denied | May 14, 2008 ACTIVITY NUMBER: T08PI00017 PROJECT NAME: Riverfront Plaza PROJECT ADDRESS: 1350 W Irvington Rd PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is required for re-submittal. The following items must be revised or added to the plan. 1. Include a response letter with the next submittal that states how all comments have been addressed. 2. See redlines on the submitted drawings and address the additional redline comments. During the next submittal please re-submit the roll of redlines for back checking purposes. 3. Provide an end median signage treatment on western bull nose per PCDOT & TDOT Signing Manual (2002) Chap 9-4A & 9-4B. 4. Show existing striping in plan view to establish tie in points for the proposed striping. 5. Provide a 'RIGHT LANE' (R3-5F) supplemental plaque under the new (R3-5R) Irvington Road. 6. Place the PIA and CDRC Case number on the cover sheet. 7. Add the following Signing General Notes 5(a) & 5(b) per PCDOT & TDOT Signing Manual (2002) (Chapter 1, Sheet 12) to the Plans. 8. Add the following Pavement Marking/Striping General Notes to the Plans: 'ALL STREET STRIPING & SIGNAGE TO BE COORDINATED WITH C.O.T. TRAFFIC ENGINEERING CALL 791-4259 A MINIMUM OF 48 HOURS PRIOR TO THE INSTALLATION OR REMOVAL OF ANY SIGNAGE OR STRIPING. ALL REQUIRED STRIPING AND SIGNAGE WILL BE INSTALLED AT THE CONTRACTOR'S EXPENSE. NEW STRIPING TO BE THERMOPLASTIC MATERIAL. USE 2" SQUARE-TUBE POST AND SQUARE TUBE POST FOUNDATIONS FOR SIGNING. BARRICADE PLAN MUST BE SUBMITTED TO THE CITY OF TUCSON TRAFFIC ENGINEERING FOR APPROVAL 48 HOURS IN ADVANCE OF ANY WORK IN PUBLIC RIGHT OF WAY.' 'THE CITY SHALL NOT BE LIABLE FOR ANY ERRORS AND/OR OMISSIONS ON THESE PLANS. ITEMS NOT MEETING CITY STANDARDS SHALL BE REPAIRED/REPLACED BY THE DEVELOPER/CONTRACTOR AND AT NO COST TO THE CITY.' If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov |
05/14/2008 | SMONTIE1 | PIA COORDINATOR | OUT TO CUSTOMER | Completed |