Plan Review Detail
Review Status: Completed
Review Details: PIA SUBMITTAL
Plan Number - T08PI00015
Review Name: PIA SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/27/2008 | SMONTIE1 | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | Please submit utility clearance letters. |
| 03/27/2008 | SMONTIE1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | Please submit utility clearance letters. |
| 03/27/2008 | SMONTIE1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | Please submit utility clearance letters. |
| 03/27/2008 | SMONTIE1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | Please submit utility clearance letters. |
| 03/27/2008 | SMONTIE1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | Please submit utility clearance letters. |
| 03/27/2008 | SMONTIE1 | UTILITY CLEARANCES | COX COMMUNICATION | Denied | Please submit utility clearance letters. |
| 03/27/2008 | SMONTIE1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | Please submit utility clearance letters. |
| 03/27/2008 | SMONTIE1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | Please submit utility clearance letters. |
| 03/27/2008 | SMONTIE1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | Please submit utility clearance letters. |
| 04/08/2008 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | April 7, 2008 SUBJECT: Lodge On The Desert, PIA T08PI0015. I-2008-015 PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal. 1. Include the plan number "I-2008-015" in title block of each sheet. 2. Include Development Services Department PIA activity number "T08000015" on cover sheet. 3. Include the development plan number on cover sheet. 4. Include Alvernon Way, Poe Street, and Holmes Street in plan's title. 5. Provide a detail for each type of proposed curb access ramp. Additionally, indicate the use of truncated domes as the detectable warning device. 6. Add the following general note: The contractor shall contact and/or coordinate any work with COT Streets & Traffic Maintenance Division, Electric Shop (791-3154) prior to relocation or placement of any street lighting or traffic facilities. Please Contact Ernie Encinas at (791-3154) for street lighting/traffic signal plan review. 7. Indicate that a 2' minimum set back per City of Tucson Development Standard 11-09.0 is required from the hinge point of any cut and fill slope on private property and the property line. 8. Scupper details have discrepancies between them. Review and revise appropriately, see redlines. 9. Sheet 2, Detail "New pavement & curb Detail": Show sidewalk and right-of-way limits. 10. Provide a profile of the proposed right turn lane on Alvernon Way. Include elevations for all ECRs, BCRs and angle points. 11. Relocate the curb access ramp on the north side of the proposed driveway entrance on Alvernon Way to be in alignment with the proposed ramp opposite of it. 12. The existing curb access ramp on the northeast corner of Poe Street and the southwest corner of Holmes Street must be brought into compliance with current ADA requirements. 13. Provide 6' wide sidewalk along Alvernon Way between Poe street and Holmes Street. The minimum sidewalk with along a roadway listed on the City of Tucson Major Streets and Routes Plan is 6' wide. 14. If the 3" waterline shown on Poe Street a private, it must be relocated onto private property. Please refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsoz.gov |
| 04/18/2008 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Denied | We have reviewed this plan and have the following comments: 1. Sheet 2 - Detail A - Please verify the thickness of the rip rap pad. Typically the thickness si two times the D50. 2. Curb Access Ramps - Please call out the use of truncated domes for all curb access ramps. 3. Will there be any landscaping installed with this project? If so, please submitt the landscape plan to Paul Rosenboom at 4004 S. Park Ave. Bld #2 for review. 4. Please coordinate all work in the right of way with Paul Rosenboom at 791-5279 ext 234 to prevent damage to existing landscaping and irrigation. Electrical 1. Sheet 3 - Please provide a note on the plan that calls for intercepting the existing conduit and re-routing it behind the new curb with new conductors. 2. Sheet 3 & 4 - Please provide a note to call Ed Serrias at 791-5279 ext 259 for inspection and instructions on the light pole and pull box relocation. No further comments |
| 04/21/2008 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approv-Cond | Any landscape or irrigation within ROW must be submitted under separate permit application. |
| 04/24/2008 | SMONTIE1 | PIA COORDINATOR | CUSTOMER CALLED | Completed | |
| 04/24/2008 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Denied | April 24, 2008 ACTIVITY NUMBER: T07PI00015 PROJECT NAME: Lodge on the Desert PROJECT ADDRESS: 306 N Alvernon Way PROJECT REVIEWER: Jose E. Ortiz PE, Traffic Engineer Resubmittal Required: Traffic Engineering does not recommend approval of the PIA Plan; therefore a revised PIA Plan is required for re-submittal. The following items must be revised or added to the plan. 1. Include a response letter with the next submittal that states how all comments have been addressed. 2. See redlines on the submitted drawings and address the additional redline comments. During the next submittal please re-submit the roll of redlines for back checking purposes. 3. Provide a 'RIGHT LANE' (R3-5F) supplemental plaque under the new (R3-5R) along Alvernon Way. 4. Place the PIA and CDRC Case number on the cover sheet. If you have any questions, I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov |
| 04/24/2008 | SMONTIE1 | PIA COORDINATOR | OUT TO CUSTOMER | Completed |