Plan Review Detail
Review Status: Completed
Review Details: PIA - RESUBMITTAL
Plan Number - T08PI00013
Review Name: PIA - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/17/2016 | LINZUNZA | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 05/17/2016 | LINZUNZA | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 05/17/2016 | LINZUNZA | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 05/17/2016 | LINZUNZA | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | |
| 05/17/2016 | LINZUNZA | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 05/17/2016 | LINZUNZA | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 05/17/2016 | LINZUNZA | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 05/17/2016 | LINZUNZA | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 05/17/2016 | LINZUNZA | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied | |
| 05/18/2016 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approved | |
| 05/25/2016 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved | |
| 05/31/2016 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approved | |
| 06/03/2016 | LINZUNZA | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | |
| 06/03/2016 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Approv-Cond | May 27, 2016 SUBJECT: Starr Pass Vistas, Village 2, offsite, PIA T08PI0013, I-2008-017 PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and recommends a conditional approval. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments and return redlined drawings with subsequent submittal. 1. Sheet 1: Revise owner and developer information if changed. 2. Sheet 1: Revise legend to include all line work and existing and proposed utilities. 3. Sheet 2: Revise drawing to indicate curb and sidewalk along the Starr Pass Road project frontage west of Castar Drive. Submit any documentation if an agreement with TDOT or a TSMR was granted for relief of this requirement. 4. Sheet 3: Revise drawing to depict existing concrete spillway apron located at +/- 31+00 RT, Greaswood Road and indicate the disposition of it. 5. Sheet 3, Detail C: Revise drawing to indicate an 8 foot wide graded shoulder. 6. Please Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
| 06/03/2016 | LINZUNZA | PIA COORDINATOR | OUT TO CUSTOMER | Completed |