Plan Review Detail
Review Status: Completed
Review Details: PIA RESUBMITTAL
Plan Number - T08PI00013
Review Name: PIA RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2010 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approved | No objection pertaining to Street Maintenence. |
| 06/29/2010 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved | |
| 07/09/2010 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSADOR | Completed | Utility plan receipts on file are over 2 years old, please resubmit plan set to utility companies and submit plan receipts with next submittal. |
| 07/09/2010 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | July 8, 2010 TO: DSD PIA Coordinator SUBJECT: Starr Pass Vistas, Village 2, offsite, PIA T08PI0013, I-2008-016, 2nd Review PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal. 1. Include all line work used on drawing in the drawing legend. 2. Change plan number from I-2008-017 to I-2008-16. 3. Reference paving plan numbers for future roadways shown on plan and clearly indicate roadways are future not existing. 4. Match existing thickened pavement edge for the pavement widening along Greaswood Road. Please refer to Paving plan I-2004-057. 5. Indicate that the minimum pavement width for the pavement widening tapers on Greaswood Road is a minimum of 2' wide. 6. Submit approved tentative plat for Starr Pass Village 1 with next plan review. Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsoz.gov |
| 07/09/2010 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed | Utility plan receipts on file are over 2 years old, please resubmit plan set to utility companies and submit plan receipts with next submittal. |
| 07/09/2010 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Denied | |
| 07/09/2010 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Denied | |
| 07/09/2010 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Denied | |
| 07/09/2010 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Denied | |
| 07/09/2010 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Denied | |
| 07/09/2010 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Denied | |
| 07/09/2010 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Denied | |
| 07/09/2010 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Denied | |
| 07/09/2010 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Denied |