Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T08OT02733
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/17/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: November 20, 2008 SUBJECT: Site Plan, Building Plan and Floodplain Use Permit TO: MPE LOCATION: 2700 E La Madera Drive, T13S, R14E, Section 32, Ward 3 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T08CM03677 (First Review) T08OT02733 RESUBMITTAL REQUIRED: Site Plan, Building Plan and Floodplain Use Permit SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan, building plan or floodplain user permit at this time. Please address the following review comments prior to the next submittal. Please include a response letter to the comments along with the corrected copies of the SP. Site Plan: 1. Unable to approve site plan until floodplain use permit requirements have been met. 2. Additional comments may be forthcoming. Building Plan: 3. Unable to approve site plan until floodplain use permit requirements have been met. 4. Additional comments may be forthcoming. Floodplain Use Permit: 5. Applicant is to inform Development Services Department - Engineering of proposed method for complying with floodplain requirements. Applicant has (2) options: A. Construct new construction to the regulatory elevation as determined by Engineering. B. Provide cost estimate with break down of the material and labor completed by a registered contractor or licensed professional (ie, architect, engineer, etc) to ensure that the improvement does not exceed the maximum 50% improvement. The 50% improvement of the structure is determined by taking the value of the structure, not to include the value of the land. Applicant has the option of hiring an appraiser or using the values determined by the Pima County Assessors office for improvement value. 6. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax ---------------------------------------------------------------------------------- DATE: December 17, 2008 SUBJECT: Site Plan, Building Plan and Floodplain Use Permit TO: MPE LOCATION: 2700 E La Madera Drive, T13S, R14E, Section 32, Ward 3 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T08CM03677 (First Review) T08OT02733 Elevation Certificate Completed so applicant can provide existing finished floor of Ramada/Comfort Station |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/06/2009 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 01/06/2009 | SUE REEVES | REJECT SHELF | Completed |