Permit Review Detail
Review Status: Active
Review Details: FLOODPLAIN
Permit Number - T08OT02249
Review Name: FLOODPLAIN
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/10/2008 | JASON GREEN | ENGINEERING | REVIEW | Approved | October 10, 2008 FLOODPLAIN USE PERMIT NO.: T08OT02249 ADDRESS: 1248 E Copper Street, Tucson Arizona 85719 PROPERTY OWNER: Scott Smithrud, 520-797-8533 The applicant is authorized to use a portion of the City of Tucson flood-prone and/or erosion hazard area as shown per the prepared Drainage Report (Civil Design Group, 13SEP08) covering this parcel as, specifically described as: A portion of Parcel 113-09-525A, Foster Lot 1 Blk 4 Exc Spandrel; For the purpose of constructing a single-family residence. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and is bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit. This floodplain use permit is issued with the following 8 conditions: 1) This project is located in a City of Tucson Floodplain as shown per the submitted Drainage Report that was prepared by Civil Design Group dated 13SEP08 for the property located at 1248 E Copper Street. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) For purposes of this permit the following flood elevations shall be used: Base Flood Elevation (BFE) = 2393.03 feet NGVD29 Regulatory Flood Elevation (RFE) = 2394.03 feet NGVD29 Residence is to have lowest finished floor elevated at or above the Regulatory Flood Elevation (RFE) and lowest point of any attached appliances is to be at or above the Regulatory Flood Elevation (RFE). 4) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the 1010/1015 inspection (P2S) and prior to finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the single-family residence as well as the identity and location of all other equipment/machinery servicing the single-family residence. 5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T)8OT02249 FOR INFORMATION PLEASE CALL 791-5550." 6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 7) All work shall conform to the approved site plan (T08CM02709), which is made part of this permit. 8) This permit is specific to the improvements for 1248 E Copper Street as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. APPLICANT NAME: Sue Pafford ADDRESS: 7945 N Carol Anne Drive Tucson, AZ 85741 PHONE: 520-241-2605 OWNER: Scott Smithrud ADDRESS: 11731 N Cassiopeia Drive Oro Valley, AZ 85737 PHONE: 520-797-8533 (EXPIRATION DATE) Month: 10 Day: 10 Year: 2009 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/04/2008 | SUE REEVES | APPROVAL SHELF | RECEIVED |