Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T08OT01108
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/26/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | June 26, 2008 FLOODPLAIN USE PERMIT # T08OT01108 PROJECT ADDRESS: 4209 E Paseo Grande APPLICANT'S NAME: Larry Vehnekamp PROPERTY OWNER: Sarah Davis This parcel lies within a City of Tucson identified 100-year floodplain, FEMA Zone X, map number 040076 C 2234K, effective date February 8, 1999. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as: 4209 E Paseo Grande, Tucson, AZ 85711, W50' OF E590.5' OF N135' OF S835' OF E2 SE4 SW4 S .15 AC P 120-15-14-14. In a portion of Township 14 South, Range 14 East, Section 15, for the construction of a new addition to an existing single family residence. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) The proposed addition to existing single family residence is located within an identified City of Tucson 100-year floodplain, as defined in The Floodplain and Erosion Hazard Management Ordinance, Chapter 26 of the Tucson Code (Ordinance). 4) For purposes of this permit the following flood elevations shall be used per hydraulic model for Approximate 100-year Flood Hazard Area along the Paseo Grande Wash by JE Fuller Engineering (Dated 7/7/06). Base Flood Elevation (BFE) = 2529.45' feet NAVD 1988 Regulatory Flood Elevation (RFE) = 2530.45' feet NAVD 1988 Finished floor of the commercial building and the lowest point of any attached appliances including water heater, air conditioning units, etc. are to be at or above the Regulatory Flood Elevation (RFE). 5) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to final approval of single family residence or electrical inspection. The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery servicing the single family residence as well as the identity and location of all other equipment/machinery servicing the single family residence. All elevation certificates are to be returned to Development Services - Engineering Department at 201 N Stone on the 1st floor - for review, approval and the release for inspections. 6) Certification is required by an Arizona State Registered Professional Civil Engineer that the finished floor of the single family residence meets all the requirements of Section 26-9 of the Ordinance. 7) All work shall conform to the approved details and general Site Plan, which are made part of this permit. 8) No electrical or electrical components are permitted below the finished floor of the addition. 9) Because the addition is being constructed on a crawl space, openings will be required. The proposed addition is to have a minimum of two openings installed with a total net area of not leass than one square inch for every square foot of enclosed area subject to flooding shall be provided. A) The bottom of all openings shall be no higher than one foot above grade. B) Openings may be equipped with screenns, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. 10) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T08OT01108 FOR INFORMATION PLEASE CALL 791-5550." 11) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 12) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 13) See the associated activity T08CM01435. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of approval. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. (EXPIRATION DATE) Month: 6 Day: 26 Year: 2009 APPLICANT/CONTRACTOR: Larry Vehnekamp ADDRESS: 4209 E Paseo Grande, Tucson, Arizona 85641 PHONE: (220) 891-0660 OWNER: Sarah Davis ADDRESS: 4209 E Paseo Grande, Tucson, Arizona 85711 PHONE: (520) 481-0014 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |