Permit Review Detail
Review Status: Active
Review Details: FLOODPLAIN
Permit Number - T08OT01097
Review Name: FLOODPLAIN
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/17/2008 | JASON GREEN | ENGINEERING | REVIEW | Approved | June 17, 2008 FLOODPLAIN USE PERMIT # T08OT01097 PROJECT ADDRESS: 6219 S Sears Boulevard APPLICANT'S NAME: Rick Engineering Company, INC PROPERTY OWNER: Sears Road Project, LLC This parcel is partially located within a regulatory 100-year floodplain per the Drainage Report (Rick Engineering Company, 21DEC07) and a regulatory riparian habitat. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as: 6219 S Sears Blvd, Tucson, AZ 85706, LOS RANCHITOS #4 LOT 159 AND 160 EXC. S125' E100' in a portion of Township 15 South, Range 14 East, Section 08, for the purpose of construction and grading within the protected riparian area, 100-year water surface elevation encroachment, construction of the wall along the east property line, etc. and all associated improvements as shown on the approved grading plan (T08BU00384). The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 8 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes or further disturbance within the floodplain and riparian area occurs other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction activity within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) All work shall conform to the approved grading plan, prepared by Rick Engineering Company, Inc., 05MAY08, which is made part of this permit. 4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T08OT01097 FOR INFORMATION PLEASE CALL 791-5550." 5) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 7) There shall be no stockpiling material, or storage of vehicles, other than that which is accepted by COT and as shown on the approved plans and SWPPP. There shall be no stockpiling or disturbance outside of disturbance limits. Construction material and vehicles shall be promptly removed once improvements are complete. 8) See the associated activity T08BU00384. This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, and Engineering Division. (EXPIRATION DATE) Month: 06 Day: 18 Year: 2009 APPLICANT/CONTRACTOR: Rick Engineering Company, Inc. ADDRESS: 1745 E River Road, Suite 101, Tucson, Arizona 85718 PHONE: (520) 795-1000 OWNER: Sears Road Project, LLC ADDRESS: 4414 N Civic Center Dr, Suite 103, Phoenix, Arizona 85251 PHONE: (520)-808-0202 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/27/2008 | SUE REEVES | APPROVAL SHELF | RECEIVED |