Permit Number: T08OT00713
Parcel: 130060030

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T08OT00713
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/05/2008 BIANCA RAMIREZ ENGINEERING REVIEW Approved December 4, 2008
FLOODPLAIN USE PERMIT NO.: T08OT00713
ADDRESS: 1844 S Alvernon, Tucson Arizona 85710 - "Building C"
PROPERTY OWNER: Ronald Gallagher
865 S Fordham Dr, Tucson Arizona 85710

The applicant is authorized to use a portion of the City of Tucson determined 100-year specifically described as:

A portion of Parcel 130-06-0030, E330' S2 NE4 EXC N750' & EXC S30' & EXC E75' THEREOF 3.79 AC SEC 21-14-14;

For the purpose of tenant improvement to charter school, an existing non-conforming floodprone structure.

In reviewing this Floodplain Use Permit application for improvements to an existing floodprone structure, it has been concluded that the cumulative value of improvements to this structure, as supported by documentation provided by the applicant, is less than 50% of the current appraised value of the existing structure.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and is bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following conditions:

1) When the improvements equal or exceed 50% of the current value of the structure; no other improvements will be permitted unless the entire structure is brought into compliance with the City of Tucson Floodplain and Erosion Hazard Area Regulations (Chapter 26, Tucson Code). If the project is determined to be a substantial improvement, and, if it is determined that the lowest flood elevation is below the regulatory floor elevation, a design submittal, and review and acceptance of the submittal for flood proofing will be required and shall conform to current City of Tucson and FEMA floodplain development requirements in effect on the date of authorization by the Development Services Department.
2) The proposed improvements shall not impose conditions that would increase the flood damage potential to the combined proposed and existing building, by 50 percent or greater of the existing structure's value.
3) A cost estimate ($76,511) was provided showing that the improvements are less than 50 % (estimate was 50%) of the assessed value of the structure (excluding land value- $1,538,449), as shown on the latest Assessors Records. No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Tucson Code. The estimate will be recorded and any future improvements will be added to it.
4) This project is located in a City of Tucson identified 00-year floodplain.
5) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
6) This Floodplain Use Permit is issued concurrently with the improvement plans/permit. Copies of these documents shall be kept in a readily accessible location on site at all times.
7) Any future permanent, freestanding walls or other structures shall have separate floodplain use permit applications submitted to this office for review and approval.
8) An application/processing fee of $50.00 (submittal fee) must accompany each future request for work to be authorized under this floodplain use permit. Engineering study review fees of $150.00 may be imposed based upon the fee schedule in the current floodplain ordinance.
9) The associated improvements are with permit activity number T08CM01009.
10) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents.
11) Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives.
12) This permit is specific to the improvements for 1844 S Alvernon as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Burns Wald Hopkins Architects
ADDRESS: 261 N Court, Tucson AZ 85701
PHONE: 520-759-2705
CONTRACTOR: Low Mountain Construction
ADDRESS: 4105 N 20th Street, Tucson AZ 85716
PHONE: 520-265-2201

(EXPIRATION DATE) Month: 12 Day: 04 Year: 2009

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/16/2008 SUE REEVES APPROVAL SHELF Completed
12/16/2008 CPIERCE1 OUT TO CUSTOMER Completed