04/22/2008 BIANCA RAMIREZ ENGINEERING REVIEW Approved April 22, 2008
FLOODPLAIN USE PERMIT # T08OT00377
PROJECT ADDRESS: 4109 E Waverly Street
APPLICANT'S NAME: Howard Bisgeier
PROPERTY OWNER: Howard Bisgeier


This parcel lies in a City of Tucson regulated 100-year floodplain. The FEMA FIRM panel number is 40076 C 2232K, effective date February 8, 1999. Federal law requires that a flood insurance policy be obtained as a condition of a federally backed mortgage or loan that is secured by a building located within a SFHA. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:
The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:

4109 E Waverly Street, Tucson, AZ 85712, FRONTIER VILLAGE AMENDED LOT 19 BLK 12. In a portion of Township 14 South, Range 14 East, Section 3, to enclose existing garage and new shed.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.

2) This parcel lies in a City of Tucson identified 100-year floodplain. Therefore, the proposed development is subject to substantial improvement requirements.

Substantial Improvement means any reconstruction, repair, rehabilitation, addition or other improvements of a structure, the cost of which equals or exceeds fifty (50) percent of the market value of the structure before the "start of construction" of the improvements. This term includes structures, which have incurred "substantial damage" regardless of the actual repair work performed.

Per Sec. 26-4.1 Nonconforming development.

(a) Improvements to, or Reconstruction of, Existing Nonconforming Development:

(1) Any structure which is substantially improved at a cost equal to or exceeding fifty (50) percent of the full cash value of the structure as shown on that latest assessment rolls of the county assessor wither (a) before the improvement or repair is started, or (b) if the structure has been damaged and is being restored, before the damage occurred, shall conform to these regulations. At the time of improvement or reconstructing the structure or development, floodproofing (non-residential structures only) may be considered as one of the means if bringing it in compliance with this chapter.

The proposed improvement is considered a substantial improvement since the house is located within a City of Tucson regulated floodplain and does not a have an elevation certificate on file. The cost of the improvements is estimated at $8,475.00. The current assessed value of the structure is $73,924.00.

The assessed value of the structure, calculated to be $73,924.00, was based on the Pima County's assessor's valuation for the improvements. Any cumulative improvements would need to be under a total 50% substantial improvement amount of $36,962.00. The current proposed improvement is 11% of the structure value, so any further improvements would result in other floodplain use permit review, flood proofing design, and/or other substantial improvement requirements.

3) See the associated activity T08CM00268.

4) The new shed is to be constructed in a manner to prevent flotation, collapse, and lateral movement.

5) The shed Must be used solely for storage, parking of vehicles, and/or building access.

6) No electrical is to service shed.

7) No machinery and equiptment which service a building such as furnace, air conditioners, heat pumps, hot water heaters, washer, dryers, elevator lift equiptment, electrical junction and curcit breaker boxes, and food freezers, etc. are permitted.

8) Shed to have a minimum of two opening installed with a total net area of not leass than one square inch for every square foot of enclosed area subject to flooding shall be provided.

a) The bottom of all openings shall be no higher than one foot above grade.
b) Openings may be equiped with screens, louvers, valves or other coverings or devices provided that they permit the entry and exit of floodwaters.

9) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T08OT00377 FOR INFORMATION PLEASE CALL 791-5550."

10) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.

11) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.


This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 4 Day: 22 Year: 2009

APPLICANT/CONTRACTOR:
ADDRESS:
PHONE:
OWNER: Howard Bisgeier
ADDRESS: 4109 E Waverly Street, Tucson, Arizona 85712
PHONE: (520)488-9145


SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/15/2008 DELMA ROBEY OUT TO CUSTOMER Completed