Permit Number: T08OT00312
Parcel: 12205046A

Address:
2102 N RALPH AV

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T08OT00312
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/09/2008 RONALD BROWN ZONING HC SITE REVIEW Approved
06/10/2008 DAVID RIVERA ZONING REVIEW Denied FROM: David Rivera
Principal Planner for:

Heather Thrall
Senior Planner

PROJECT: T08OT00312, 2102 N. Ralph Avenue
5 new apartment units
Commercial Site plan, 2nd Review

TRANSMITTAL DATE: May 6, 2008

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. It is clear that the building setback has not been addressed on the site plan. In the review of the building plans it was found that the top of parapet from the finish floor is labeled as 21'-0". Detail 2 on sheet A2 of 7 of the building plan set indicates the design grade is 8 inches below the finish floor elevation. Based on this information the building setback along the north property line must be 16.25 feet from the property line. Per the site plan, the building setback along the north property line is labeled as 15.75 feet. Prior to approval of the site plan a DDO approval would be required. The parapet may be lowered 8 inches which would be sufficient in order to approve the proposed setback.

Previous Comment: Per DS 2-02.2.1.6, regarding buildings:
A) note height is from GRADE to flat roof then note height from grade to top of parapet.




RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan/building plans.
06/18/2008 PETER MCLAUGHLIN NPPO REVIEW Approved
06/18/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Approved
06/23/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied The revised site drawing shows the rim elevation of the next downstream manhole. Provide the rim elevation of the next upstream sanitary manhole. Determine the need for a backwater valve per Section 710.1, UPC 2006, as amended by the City of Tucson. Note that any waste piping from floors located above the floor requiring a backwater valve shall not discharge through the backwater valve.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/09/2008 DELMA ROBEY OUT TO CUSTOMER Completed
07/09/2008 SUE REEVES REJECT SHELF Completed