Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T08CM04020
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/16/2009 | DAVE MANN | FIRE | REVIEW | Approved | |
| 04/20/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 04/21/2009 | ERIC NEWCOMB | ZONING HC SITE | REVIEW | Approved | |
| 04/23/2009 | GERRY KOZIOL | WWM | REVIEW | Denied | need to build public sewer need to show location/method of connection to public sewer |
| 05/05/2009 | RICK MYERS | PLUMBING-COMMERCIAL | REVIEW | Denied | Comment still not resolved: riser diagrams 2/P4.0, 2A/4.0, 4A/P4.0, 5/P4.0, 7/P4.0, 8/P4.0, 10/P4.1, 11/P4.1, 13/P4.1, 15/P4.1, and 19/P4.1, do not reflect the fixture, vent, or stack arrangements, or the pipe sizes shown on the plumbing floor plans. coordinate the riser diagrams shown on sheets P4.0, and P4.1 with the plumbing floor plans. Reference: Section 103.2.3, 2006 UPC. |
| 05/06/2009 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Show how the installation of EF-8 complies with the requirements of Section 506.3.12.3, IMC 2006. 2. Clarify the type of wall located on the west side of the proposed location for the Type I hood; it appears to be a type L wall which has wood studs. To comply with the requirements of Section 507.9, IMC 2006, a zero-clearance wall within 18" of a Type I hood shall have non-combustible supports and a smooth, non-absorbent, non-combustible material between the hood and the gypsum wall board. |
| 05/06/2009 | ROBERT SHERRY | WATER | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/20/2009 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 05/20/2009 | SUE REEVES | REJECT SHELF | Completed |