Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T08CM03975
Parcel: Unknown

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T08CM03975
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2009 THAUSER1 ELECTRICAL-COMMERCIAL REVIEW Needs Review
12/24/2008 LOREN MAKUS ENGINEERING REVIEW Approved
12/24/2008 MICHAEL ST. PAUL ZONING REVIEW Approved
12/24/2008 MARTIN BROWN FIRE REVIEW Approved
12/26/2008 GERRY KOZIOL WWM REVIEW Approved
12/26/2008 ERIC NEWCOMB ADA REVIEW Passed
12/26/2008 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
12/26/2008 ERIC NEWCOMB ZONING HC SITE REVIEW Approved
12/26/2008 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
12/31/2008 ROBERT SHERRY WATER REVIEW Denied 1. Provide the size of the existing water meter and the total connected water demand that will result from the addition of this activity. The maximum demand that Tucson Water will allow with a 1" meter is 25 GPM. Reference: Sections 610.1 and 610.2, UPC 2006.
2. Verify that the water meter can be located in the basement of the building.
3. Reduced pressure backflow prevention assemblies are required to be installed in locations accessible to Tucson Water. Confirm that the basement location is acceptable to Tucson Water. Reference: COT Ordinance 9976, http://www.tucsonaz.gov/water/docs/backflow-ord.pdf
4. If the backflow preventer is to be located in the basement, show how the drainage from the assembly will be accommodated. Reference: Section 603.3.9, UPC 2006.
12/31/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. If hot water will be supplied, show how the temperature of the hot water supply to the public lavatories will be controlled to a maximum temperature of 110 degrees Fahrenheit. Reference: Section 413.1, UPC 2006 and Section 504.3, IECC 2006.
2. Provide a floor drain in the restroom. Reference: Section 411.2, UPC 2006.
3. Calculate the water demand using the fixture units shown in Tables 6-5 or A-2. Reference: Section 610.3, UPC 2006.
4. Provide the minimum plumbing facilities required by Table 2902.1 and Section 2902.2, IBC 2006, for business occupancy (e.g. a service sink and a drinking fountain).
12/31/2008 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approv-Cond Deferred submittal:
1. Mechanical A/C units,
2. Elevator equipment room A/C,
3. Condensate drains (size, route, and termination) for all mechanical units.
4. Exhaust fans and ducts for restrooms

Final Status

Task End Date Reviewer's Name Type of Review Description
01/02/2009 THAUSER1 OUT TO CUSTOMER Completed