Permit Number: T08CM03911
Parcel: 107130150

Address:
202 E GLENN ST

Review Status: Completed

Review Details: RESIDENTIAL W/ COMM BLDG/ZONING/ENGINE

Permit Number - T08CM03911
Review Name: RESIDENTIAL W/ COMM BLDG/ZONING/ENGINE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2009 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Passed
12/23/2008 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. 3/32" LETTERING ON ALL DRAWINGS IS REQUIRED UNLESS A WRITTEN APPEAL FOR 1/16" IS APPROVED BY THE BUILDING OFFICIAL, JESSIE SANDERS. THIS APPROVED APPEAL MUST ACCOMPANY DRAWINGS SUBMITTED FOR CHECKING.
2. SHEET A2; KEYNOTE 12: CLARIFY TUBE WALL THICKNESS.
3. SHEET A2; CARPORT FRAMING PLAN: CLARIFY THE LOCATION OF THE RADIUS DIMENSIONS ORIGIN POINT (21'-5") AND RADIUS ORIGIN POINT (36').
4. SHEET A3; DETAILS 2 AND 7: PROVIDE DIMENSIONS FROM TOP OF EXISTING CMU WALL TO NEW FRAMING.
5. SHEET A3; DETAIL 5: INDICATE GROUT PACK TO CORRECT LOCATION.
6. SHEET A5: ADD NOTE FOR REQUIRED SPECIAL INSPECTIONS.
7. SHEET A5; STRUCTURAL STEEL NOTE 1: COMPLETE NOTE FOR SIDE LAP SCREW SIZE.
8. GENERAL: PROVIDE ELEVATIONS OF FOOTINGS/ STEEL FRAMING AT ROOF/ FRAMING AT FLOOR FOR FABRICATION AND CONSTRUCTION PURPOSES.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/15/2009 THAUSER1 OUT TO CUSTOMER Completed