Review Date Reviewer's Name Type of Review Description Status Comments
01/09/2009 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Approved
12/17/2008 BIANCA RAMIREZ ENGINEERING REVIEW Approved December 17, 2008
FLOODPLAIN USE PERMIT NO.: T08OT02927
ADDRESS: 2610 E Florence Drive, Tucson Arizona 85716
PROPERTY OWNER: Gene De La Cruz

The applicant is authorized to use a portion of the City of Tucson identified 100-year floodplain, specifically described as:

A portion of Parcel 112-04-0320, LA MADERA LOT 31 BLK 1;

For the purpose of adding a Bedroom, Bathroom, and Remove & Repair exterior wall to patio, to an existing non-conforming floodprone structure.

In reviewing this Floodplain Use Permit application for improvements to an existing floodprone structure, it has been concluded that the cumulative value of improvements to this structure, as supported by documentation provided by the applicant, is less than 50% of the current appraised value of the existing structure.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard Area Regulations, and is bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations require application for, review and approval of an additional Floodplain Use Permit.

This floodplain use permit is issued with the following conditions:

1) Improvements equal or exceeding 50% of the current value of the structure will require full complianca; no other improvements will be permitted unless the entire structure is brought into compliance with the City of Tucson Floodplain and Erosion Hazard Area Regulations (Chapter 26, Tucson Code). If the project is determined to be a substantial improvement, and, if it is determined that the lowest flood elevation is below the regulatory floor elevation, a design submittal, and review and acceptance of the submittal for flood proofing will be required and shall conform to current City of Tucson and FEMA floodplain development requirements in effect on the date of authorization by the Development Services Department.
2) The proposed improvements shall not impose conditions that would increase the flood damage potential to the combined proposed and existing building, by 50 percent or greater of the existing structure's value.
3) Per Building Residential Valuation Calculation for T08CM03899 on 09/01/2008 an estimate of ($35,488.53) was provided showing that the improvements are less than 50 % (estimate was 30%) of the assessed value of the structure (excluding land value calculated by taking 80% of the total 2008 value - $118,552), as shown on the latest Assessors Records. No person shall repair or alter property in a piecemeal manner so as to avoid the provisions of Section 26-4.1.a.3, Chapter 26-Tucson Code. The estimate will be recorded and any future improvements will be added to it.
4) This project is located in a City of Tucson identified 100-year floodplain.
5) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
6) This Floodplain Use Permit is issued concurrently with the improvement plans/permit. Copies of these documents shall be kept in a readily accessible location on site at all times.
7) Any future permanent, freestanding walls or other structures shall have separate floodplain use permit applications submitted to this office for review and approval.
8) An application/processing fee of $50.00 (submittal fee) must accompany each future request for work to be authorized under this floodplain use permit. Engineering study review fees of $150.00 may be imposed based upon the fee schedule in the current floodplain ordinance.
9) The associated improvements are with permit activity number T08CM02899.
10) The applicant attests to the fact that the plans and documents submitted represent all of the improvements that will be done to the existing building, and that all additions, improvements or repairs to the building are included in the construction plans and/or documents herewith. No other improvements, repairs, reconstruction, additions or remodeling have been made to the structure that is not indicated in the attached plans and/or documents.
11) Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives.
12) This permit is specific to the improvements for 2610 E Florence Drive, as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Gene De La Cruz
ADDRESS: PO Box 35098, Tucson AZ 85704
PHONE: 520-907-6634
OWNER: Gail Emerick
ADDRESS: 2220 N Norton Ave, Tucson AZ 85719
PHONE:

(EXPIRATION DATE) Month: 12 Day: 17 Year: 2009

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.
12/26/2008 GERRY KOZIOL WWM REVIEW Approved