Permit Number: T08CM03859
Parcel: 130060030

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T08CM03859
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/26/2008 DAVE MANN FIRE REVIEW Approved
06/26/2008 ANDREW CONNOR NPPO REVIEW Denied
06/26/2008 ANDREW CONNOR LANDSCAPE REVIEW Approved
06/26/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the site drawing to include the following information:
a. The first floor elevation of the building
b. the location and size of the public sanitary sewer and
c. the location, invert, and rim elevation of the upstream manhole
Reference City of Tucson Development Standard No. 2-05.0 2.3 and Section 103.2.3, UPC 2006
06/26/2008 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Griffin Foundation - Expansion
T08CM01009
Site Plan (2nd Review)

TRANSMITTAL DATE: June 30, 2008

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the effected areas.

2. Zoning acknowledges that a Special Exception will be applied for. If approved provide the Special Exception number, date of approval and any conditions on the plan. This project is located within the Davis-Monthan Air Force Base AIRPORT ENVIRONS ZONE (AEZ), Noise Control District - NCD-A - 65-70 Ldn. Per LUC Section 2.8.5.9.A.2.a.2 Educational Use - Elementary and Secondary is a prohibited use. Zoning acknowledges that the Davis Monthan Airport Environs Zone map was amended October 25, 2004 thus giving the existing use non-conforming status. Based on current code an expansion of use is not allowed.

3. Per the note on the provided site plan C-1 dated June 28, 2005 the play area was limited to 3,450 SF. The area on the plan exceeds this square footage. To expand the area a Special Exception is required. It appears that playgrounds are proposed along the west property line. Per LUC Section 3.5.3.7.D. Outdoor Activity. All outdoor activity shall be held more than fifty (50) feet away from the property line where adjacent to R-3 or more restrictive zoning. The use of loudspeakers, amplifiers, or similar type equipment outdoors is not permitted on the school site within one hundred (100) feet of the property line where adjacent to R-3 or more restrictive zoning. This said the playgrounds cannot be located as shown on the plan.

4. This comment was not addressed. Show the existing site lighting on the plan. D.S. 2-02.2.1.A.25 If applicable provide existing and proposed freestanding lighting layout and type. Provide a detail; list the height of pole and type of lighting.

5. This comment was made in error. Minimum width for a two-way Parking Area Access Lane is twenty-four (24) feet. That said the minimum width for an entry/exit gate is twenty-four (24) feet. The proposed entry gate must be twenty (20) feet wide

6. The provided parking calculation appears to be incorrect. Zoning was only able to find 121 parking spaces on site, please clarify.

7. If the Special Exception is approved and once the above comments have been addressed Zoning is willing to provide an over-the-counter review. Please call or email to schedule an appointment for this review.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t08cm01009-2nd

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
06/26/2008 BIANCA RAMIREZ ENGINEERING REVIEW Approved
12/10/2008 RONALD BROWN ZONING HC SITE REVIEW Denied 30 JUNE 2008
T08CM01009 - GRIFFIN FOUNDATION CHARTER SCHOOL
REVIEWED BY RON BROWN

RESUBMITTAL ACCESSIBLE REVIEW
2006 IBC/ANSI-117.1

DENIED: SEE COMMENTS BELOW

1. DENOTE GOVERNING ACCESSIBILITY CODE IS 2006 IBC/ICC 117.1.
COMMENT:
CONSTRUCTION CODE COMPLIANCE FOR THIS PROJECT IS GOVERENED BY THE 2006 IBC. AS PER CHAPTER 11, ACCESSIBILITY IS TO BE AS PER THIS CODE AND (ANSI) ICC 117.1.
2. MAINTAIN PUBLIC WAY ACCESS SOUTH OF THE SOUTH ENTRY DRIVE ENTRANCE, PROVIDE A NEW MARKED CROSSING WITH CURB RAMPS AT EITHER SIDE FOR ACCESSIBLE ROUTE; ICC 117.1 SECTION 406. PROVIDE DETECTABLE WARNINGS AT EACH CURB RAMP AS PER ICC 117.1 406.12.
COMMENT:
CURB RAMPS MUST BE IN ACCORDANCE WITH ICC 117.1, SECTION 406. THE RAMPS DEPLETED ON AO.1 ARE NOT IN COMPLIANCE.
3. OK
4. FROM THE TWO ACCESSIBLE PARKING SPACES IN FRONT OF BUILDING "B" TO THE CONCRETE ACCESSIBLE ROUTE AT BUILDING "A", MAINTAIN A RAISED MARKED CROSSING WITH CURB RAMPS AT EITHER SIDE FOR ACCESSIBLE ROUTE; ICC 117.1 SECTION 406. PROVIDE DETECTABLE WARNINGS AT EACH CURB RAMP AS PER ICC 117.1 406.12.
COMMENT:
NOTE ELEVATION DIFFERENCE OF CONCRETE WALKWAY (ACCESSIBLE ROUTE) AND ASPHALTIC PAVING AT THE MARKED CROSSING. IF THERE IS A DIFFERENCE, PROVIDE CURB RAMPS OR SIDEWALK RAMPS AS PER ICC 117.1, SECTIONS 405 AND 406. IF THE ELEVATIONS ARE FLUSH, INSURE DETECTABLE WARNINGS ARE PROVIDED AT BOTH ENDS OF THE MARKED CROSSINGS AS PER ICC 117.1, SECTIONS 406.12 AND 406.14.
5. CONFIRM, VERIFY AND DETAIL THE RELOCATED ACCESSIBLE PARKING SPACE NEXT TO THE NEW PASSENGER LOADING ZONE SO THAT IT MEETS ALL ACCESSIBLE REQUIREMENTS OF ICC 117.1 SECTIONS
406 AND 502.
COMMENT:
NOTE ELEVATION DIFFERENCE OF CONCRETE WALKWAY (ACCESSIBLE ROUTE) AND ASPHALTIC PAVING AT THE ACCESSIBLE PARKING ASILE. IF THERE IS A DIFFERENCE, PROVIDE A CURB RAMP OR SIDEWALK RAMP AS PER ICC 117.1, SECTIONS 405 AND 406. IF THE ELEVATIONS ARE FLUSH, PLEASE NOTE SUCH.
6. OK
7. OK
8. OK

END OF REVIEW
12/10/2008 JOSE ORTIZ DOT TRAFFIC REVIEW Denied The Gate/Fence locations are not acceptable to TDOT-Traffic. Alvernon Way is an arterial roadway; therefore vehicles that are unable to access the site when gates are closed are not permitted to backup onto Alvernon Way. A meeting may be needed to discuss options for gate/fence layouts.

To schedule a meeting I can be reached at 791-4259 x76730 or Jose.Ortiz@tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
12/10/2008 SUE REEVES OUT TO CUSTOMER Completed