Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM03830
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/09/2008 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 12/26/2008 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T08CM03830 12/29/08 9700 E. NICARAGUA PL. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, IECC AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FLOOR PLAN: 1. PLEASE ILLUSTRATE THE LOCATIONS OF THE BRACED WALL PANELS ON THE 54'-2" WALL. 2. THE PROPOSED FLOOR PLAN / A3 REFERS TO THE BRACED WALL PANELS AS TYPE 1 AND TYPE 2 BUT THEY'RE REFERRED TO AS TYPE A AND B ON PAGE A5. PLEASE CO ORDINATE. 3. PROPOSED FLOOR PLAN / A3 ; SHOULD SECTION 1/A4 BE IDENTIFIED AS 1/A5? SECTIONS - DETAILS - MISC. NOTES: 1. 7 / A7 ; PLEASE CHANGE THE REFERENCE FOR THE VENT CITED AS ON SHEET 7A TO BE ON A7. 2. 7/A7 ; PLEASE PROVIDE JUSTIFICATION OF THE PERF METAL PROVIDING 1:150th OF 22.5" X 16'5" FREE AIR FOR VENTILATION. R806. 3. 9 / 7 ; ILLUSTRATE THE FIRE BLOCKS AT THE CEILING LINE. R602.8 MECHANICAL PLANS: 1. JUSTIFY THE EXISTING DUCT SIZE FOR THE 5 TON HEAT PUMP. M1403 , M1601.1 ELECTRICAL PLANS: 1. PROVIDE SMOKE ALARMS FOR THE EXISTING AND THE PROPOSED BEDROOMS AND IMMEDIATELY OUTSIDE THE BEDROOMS. R313.2.1 2. PROVIDE ARC-FAULT PROTECTION FOR THE BEDROOM OUTLETS. E3802.12 3. THE SUB-PANEL IN THE LAUNDRY REQUIRES A 30" WIDE WORKING AREA IN FRONT OF THE PANEL. E3305.1 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 837-4910 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/06/2009 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 01/06/2009 | SUE REEVES | REJECT SHELF | Completed |