Permit Number: T08CM03829
Parcel: 13613040A

Review Status: Completed

Review Details: COMMERCIAL NEW

Permit Number - T08CM03829
Review Name: COMMERCIAL NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/26/2009 DAVE MANN FIRE REVIEW Denied Fire sprinklers are required, distance to fire hydrant is over 300 feet and access does not meet the Development Standards.
02/26/2009 RONALD BROWN ZONING HC SITE REVIEW Approved
02/26/2009 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. THIS PROJECT WILL REQUIRE TWO FULL SIZED SETS OF DRAWINGS AND TWO SETS OF CALCULATIONS.
2. SHEET C1.1; FOUNDATION NOTES 1 AND 2: THE CITY OF TUCSON AMENDMENTS TO THE 2006 IBC, SECTION 1805.2, STATES: 'THE MINIMUM DEPTH OF FOOTINGS BELOW THE UNDISTURBED GROUND SURFACE SHALL BE 12" FOR 1000 PSF MAXIMUM ALLOWABLE FOUNDATION PRESSURE AND A MINIMUM OF 18" FOR MAXIMUM ALLOWABLE FOUNDATION PRESSURE VALUES OF TABLE 1804.2'. REVISE NOTES, CALCULATIONS AND PLANS AS REQUIRED TO MEET THIS STANDARD.
03/02/2009 TERRY STEVENS ZONING REVIEW Denied 03/02/2009

Development Services Department
Zoning Review Section

Terry Stevens
Lead Planner

Comments:

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the building plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next building plan submittal.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved site plan. Additional comments may be forthcoming.
03/02/2009 JOHN WILLIAMS COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed Impact Fee's Do Apply; Southeast District; 3,873 Square Foot Barn; $13,307.29
03/06/2009 GERRY KOZIOL WWM REVIEW Passed
03/10/2009 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
03/10/2009 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed No plumbing shown for barn.
03/10/2009 ROBERT SHERRY WATER REVIEW Passed No water supplied to barn.
03/16/2009 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Passed
03/24/2009 PAUL MACHADO ENGINEERING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/16/2009 CINDY AGUILAR OUT TO CUSTOMER Completed
04/16/2009 SUE REEVES REJECT SHELF Completed