Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T08CM03761
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/01/2010 | GERRY KOZIOL | WWM | REVIEW | Denied | JULIAN WASH GREEWAY-COMFORT STATION/MODEL AND ALTERNATE MODEL PLAN A- PUBLIC RECREATIONAL FACILITY AT SFR RATE NEED PCRWRD REVIEW & APPROVAL CONNECTION TO PUBLIC SEWER- NEED PCRWRD REVIEW & APPROVAL OF A MANHOLE TAP- 740-6369 |
| 04/12/2010 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Approv-Cond | DATE: March 8, 2010 TO: Richard Macias, PE, Olsson Associates, Clint Glass, PE, CMG Drainage, & Walt Rogers, RLA, Acacia Group SUBJECT: Julian Wash Greenway park improvements Site & Grading Review 4TH Resubmittal LOCATION: 7501 S KOLB RD, T15S R15E Secs20, 21, 27, & 28, Ward 4 REVIEWER: Elizabeth Leibold, PE ACTIVITIES: T08OT02777 (Floodplain Use Permit), T08CM03761, T08BU02059 FLOODPLAIN: Balanced Basin Management Plan, FIRM 2855K SUMMARY: The subject property and proposed improvements are located within a Zone A SFHA as shown on the Flood Insurance Rate Map (FIRM), Community- Panel No. 04019C-2855K, effective date February 8, 1999. Pedestrian crossings, erosion protection improvements, and other drainage structures are proposed to accommodate for the proposed Julian Wash Greenway Park. Engineering Division of the City of Tucson Planning & Development Services Department has received and reviewed the resubmittal package. The resubmittal has addressed the majority of the comments and site and grading comments are addressed; therefore Engineering recommends conditional approval of the plans with the following condition to be met prior to picking up permits. CONDITION OF APPROVAL: 1) DS Sec.10-02.2.3.1.5.G: If the project grading construction is proposed to begin before the annexation, as referenced in letter dated October 20, 2008 from Pima County Parks & Rec, then the following comments applies. The project appears to cross several parcels owned by several owners including Az Board of Regents, Arizona Glass Properties, and Pima County. For drainage improvements on more than one parcel, either a recorded drainage easement or written permission must be obtained from the appropriate property owner(s) prior to issuance of Grading Permits and Building Permits. Although plans may be conditionally approved, place a note on the Site Plan and Grading Plan, which indicates previous sentence. If drainage improvements are proposed for offsite areas other than parcels owned by the City of Tucson, written approval from the offsite property owner(s) will be required. Submit 2 copies of the supporting documentation, and response letter prior to picking up permits. I can be reached at 837-4934 if you have questions. Elizabeth Leibold, PE, CPM, CFM Civil Engineer Engineering Division Planning & Development Services Department |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/15/2010 | CPIERCE1 | OUT TO CUSTOMER | Completed |
| 04/15/2010 | SUE REEVES | REJECT SHELF | Completed |