Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T08CM03757
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/11/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 02/11/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. A backwater valve has been added on sheet C-4 per Section 710.1, UPC 2006, as amended by the City of Tucson. This will require the modification of the venting for the building. Reference: Section 904.1, UPC 2006. 2. The branch water pipe serving the urinal is called out as ¾"; this will result in a water velocity greater than 8 FPS (the flush valve for a urinal requires a flow rate of approximately 15 GPM). Limit the water velocity to less than 8 FPS for the copper piping. Reference: Section A 6.1, UPC 2006 and IS 3-2003, Section 2.6. 3. Provide a vent for the flow control device for the hydromechanical grease interceptor per the manufacturer's installation instructions and Section 1014.2.1, UPC 2006. 4. Provide a vent and a clean out downstream of the hydromechanical grease interceptor. Reference: Sections 707.4, 707.8, and 1014.2.3, UPC 2006. |
| 02/11/2009 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide energy code compliance calculations for the building envelope (mechanical and lighting energy calculations have been received) using the correct climate zone for Pima County < 4,000 feet. Reference: Sections 101.4 and 104.2, International Energy Conservation Code 2006. 2. Revise the condensate drains for the evaporators in the walk-in coolers and the walk-in freezer to comply with Section 307.2.2, IMC 2006, as amended by the City of Tucson (i.e. the combined condensate drain pipe for any two units shall be a minimum of 1" in size). |
| 02/11/2009 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 02/12/2009 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/17/2009 | SUE REEVES | OUT TO CUSTOMER | Completed |
| 02/17/2009 | SUE REEVES | REJECT SHELF | Completed |