Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T08CM03705
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/21/2008 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 11/24/2008 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | 1. SHEET G001: A. CORRECT ACCESSIBILITY REFERENCE CODE TO 2006 IBC, CHAPTER 11 AND ICC/ANSI 117.1 B. CORRECT ELECTRICAL CODE REFERENCE TO 2005 NATIONAL ELECTRICAL CODE 2. DETAIL 4/A101: CLEARIFY SECTION SHOWN FOR WATER HEATER AND MOP SINK. IT DOES NOT REFLECT DESIGN SHOWN ON FLOOR PLAN, ELEVATIONS AND PLUMBING PLAN. |
| 11/24/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Passed | 1. INSURE 2'-10" HIGH ACCESSIBILITYN PORTION OF SALES DESK AS PER ANSI 117.1, SECTION 904. |
| 11/24/2008 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 11/26/2008 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 11/26/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | 1. The applicable code for all commercial plumbing projects is the 2006 Uniform Plumbing Code with Local Amendments. Provide an approved appeal to the building official if the plans are to be reviewed to the 2006 IPC. 2. Revise the north arrow on the plumbing plan to show the correct orientation of the building. Reference: Section 103.2.3, UPC 2006. 3. Provide details and structural calculations to show how the proposed water heater is to be supported from the building structure in an "approved manner". Reference: Section 314.5, UPC 2006. 4. Provide a vacuum relief for storage-type water heaters located above any fixture outlets. Reference: Section 608.7, UPC 2006. |
| 11/26/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | 1. Provide energy code compliance calculations for the building envelope. Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation. Reference: Sections 101.4 and 104.2, International Energy Conservation Code 2006. 2. The 2006 International Building Code with Local Amendments and the 2006 International Energy Compliance Code with Local Amendments are the relevant codes for this project (see items 7A and 11 in the Mechanical Specifications, sheet M103). |