Permit Number: T08CM03689
Parcel: 13213057A

Address:
1031 E BENSON HY

Review Status: Completed

Review Details: SITE

Permit Number - T08CM03689
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/21/2008 MARTIN BROWN FIRE REVIEW Approved
11/21/2008 RBROWN1 ADA REVIEW Passed NOT A COT PROJECT
11/21/2008 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens
Lead Planner

PROJECT: T08CM03689
Motel 6 #271 - 1031 E. Benson Hwy
Site Plan

TRANSMITTAL DATE: 11/21/08

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the areas of revised accessibility.

2. Provide a copy of the last approved site plan with this submittal. The provided site plan appears to have been for a proposed addition that was not constructed.

3. D.S. 2-02.2.1.12 Provide a dimension for the width of the parking area access lane (PAAL) between the proposed accessible vehicle parking spaces and what appears to be some type of planter. Per D.S. 3-05.2.1.C.1 the minimum width of a two-way PAAL is twenty-four (24) feet not 21'-2" as indicated.

4. If this plan is considered an ALTA survey the plan must be sealed by the surveyor which performed the survey.


If you have any questions about this transmittal, please contact me at Terry.Stevens@tucsonaz.gov or (520) 837-4961.
11/21/2008 RONALD BROWN ZONING HC SITE REVIEW Denied 1. THE ACCESSIBLE PARKING NEEDS TO BE DISPURSED THROUGHOUT THE SITE IN A MORE EQUITABLE FASHION SO AS TO HAVE A MORE DIRECT ACCESS TO THE ACCESSIBLE SLEEPING UNITS.
2. THE TWO MARKED CROSSING COULD BE COMBINED INTO ONE MARKED CROSSING DIRECTLY ALIGNED WITH THE WALKWAY DIRECTLY IN FRONT OF THE BUILDING. THIS WILL ALSO ELIMINATE THE NEED FOR A RAMP AND HANDRAILS.
3. PROVIDE LARGE SCALE DETAILS OF BOTH ENDS OF ACCESSIBLE ROUTE. SHOW ALL DIMS, SLOPES (SPOT GRADES), MATERIAL FINISHES, RAMPS AND DETECTABLE WARNINGS REQUIRED BY ICC/ANSI SECTIONS 405 AND 406.
4. PROVIDE SPOT GRADES ALONG ALL NEW ACCESSIBLE ROUTES OR OTHERWISE INDICATE SLOPE COMPLIANCE WITH ICC/ANSI 117.1, SECTION 403.3
5. REFERENCE "PARK WISE" FOR ACCESSIBLE PARKING SIGNAGE. CONTACT DAN ANGEL, 429-3318.
5. BOTTOM OF MAIN ACCESSIBLE SIGNAGE TO BE 74".
6. PROVIDE ACCESSIBLE PARKING AT THE SWIMMING POOL.
12/03/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Passed
12/03/2008 PETER MCLAUGHLIN NPPO REVIEW Passed
12/19/2008 LOREN MAKUS ENGINEERING REVIEW Approved
12/23/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
12/23/2008 GERARDO BONILLA OUT TO CUSTOMER Completed
12/23/2008 SUE REEVES REJECT SHELF Completed