Permit Number: T08CM03663
Parcel: 117050810

Address:
305 N HERBERT AV

Review Status: Completed

Review Details: COMMERCIAL-BLDG/FIRE/ZONING/ENG

Permit Number - T08CM03663
Review Name: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/17/2008 MARTIN BROWN FIRE REVIEW Approved
12/17/2008 BIANCA RAMIREZ ENGINEERING REVIEW RECEIVED See the floodplain use permit T08OT02678.

November 12, 2008
FLOODPLAIN USE PERMIT # T08OT02678
PROJECT ADDRESS: 305 N Herbert Ave
APPLICANT'S NAME: Bob Lanning
PROPERTY OWNER: Scott and Brian Cummings


This parcel lies in a FEMA Zone AE map number 040076 C 2227K, effective LOMR date November 2, 2001. Federal law requires that a flood insurance policy be obtained as a condition of a federally backed mortgage or loan that is secured by a building located within a SFHA. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:

305 N Herbert Ave, Tucson, AZ 85705, TUCSON LOT 12 & S49.5' LOT 9 BLK 74. In a portion of Township 14 South, Range 13 East, Section 12, for the installation of a scuplture.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.

2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

3) The proposed sculpture is located within an FEMA Zone AE, as defined in The Floodplain and Erosion Hazard Management Ordinance, Chapter 26 of the Tucson Code (Ordinance).

4) Sculpture is to be installed per plan completed by Lanning Architecture, signed and sealed by Robert Scott Lanning, RA (Dated 10/10/08).

5) Sculpture to be securely anchored to prevent flotation, collapsing or lateral movement.

6) Sculpture to be constructed per plan - must be constructed of flood resistant material.

7) All work shall conform to the approved details and general Site Plan, which are made part of this permit.

8) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T08OT02678. FOR INFORMATION PLEASE CALL 791-5550."

9) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.

10) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.

11) Contractor will need to call for floodplain use permit inspections by Development Services Department Engineering Division Inspection Team (791-5550) prior to and after the installation of the sculpture.

12) See the associated activity T08CM03663.


This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of approval. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 11 Day: 12 Year: 2009

APPLICANT/CONTRACTOR: Bob Lanning
ADDRESS: 1202 E Broadway #104, Tucson, Arizona 85719
PHONE: (520) 792-0265
OWNER: Scott and Brian Cummings
ADDRESS: 323 E 8th Street, Tucson, Arizona 85705
PHONE: (520) 770-9300


SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.
12/17/2008 MICHAEL ST. PAUL ZONING REVIEW Approved
12/18/2008 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
01/16/2009 SUE REEVES APPROVAL SHELF Completed
01/16/2009 THAUSER1 OUT TO CUSTOMER Completed