Permit Review Detail
Review Status: Active
Review Details: COMMERCIAL TI
Permit Number - T08CM03512
Review Name: COMMERCIAL TI
Review Status: Active
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/31/2008 | ANY | WWM | REVIEW | Active | |
11/03/2008 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
11/03/2008 | DAVE MANN | FIRE | REVIEW | Approved | |
11/03/2008 | JOHN WILLIAMS | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
11/04/2008 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Revise the font size used on the drawings to a minimum of 1/8-inch (all upper case). (A 3/32" font may be allowed with an appeal to the building official.) Reference: Section 106.1.1, IBC 2006. 2. The applicable code for all commercial plumbing projects is the 2006 Uniform Plumbing Code with Local Amendments. Provide an approved appeal to the building official if the plans are to be reviewed to the 2006 IPC. 3. Revise the water isometrics and the waste and vent isometrics to clearly show the proposed work. Reference: Section 103.2.3, UPC 2006. 4. Provide a design for the mounting shelf for the water heater along with structural calculations to show that the water heater is safely supported. Reference: Sections 310.0 and 314.5, UPC 2006. 5. Given the temperature range of the water supply in Tucson (as high as 90.3 degrees Fahrenheit), specify how the temperature limit stop on the lavatory faucet is to be adjusted to guarantee a maximum delivery temperature of 110 degrees Fahrenheit. Reference: Section 413.1, UPC 2006 and Section 504.3, IECC 2006. 6. Provide an expansion tank or other approved device for controlling thermal expansion for the storage-type water heater. Reference: Section 608.3, UPC 2006. 7. Verify that the installation of the vacuum relief valve conforms to the manufacturer's listing and installation requirements (e.g. shut off valve locate between the relief valve and the water heater). Reference: Section 301.1.1, UPC 2006. |
11/04/2008 | ROBERT SHERRY | WATER | REVIEW | Approved | |
11/04/2008 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | MIN SIZED LETTERING TO BE 1/8" |
11/04/2008 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Revise the font size used on the drawings to a minimum of 1/8-inch (all upper case). (A 3/32" font may be allowed with an appeal to the building official.) Reference: Section 106.1.1, IBC 2006. |
11/04/2008 | ERIC NEWCOMB | ZONING HC SITE | REVIEW | Denied | 1. NEED VERTICAL GRAB BAR 2. WATER FOUNTAIN NOT COMPLIANT, NEED HI/LOW OR SINGLE POINT OF USE |
11/04/2008 | ENEWCOM1 | ADA | REVIEW | Passed | NOT A COT PROJECT |