Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM03430
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/23/2008 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 11/20/2008 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T08CM03430 11/20/08 4026 E. 4th ST. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, ENERGY (2006 IECC) AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. 4. ALL ENGINEERS AND ARCHITECTS INVOLVED IN THE DESIGN OF THE STRUCTURE ARE TO SEAL THE RELATED SHEETS OF PLANS, DETAILS AND CALCULATIONS. THIS IS IN ACCORDANCE WITH THE RULES OF THE STATE BOARD OF TECHNICAL REGISTRATION. FLOOR PLANS: 1. GROUND FLOOR PLAN / 2 ; PLEASE NOTE THAT THE MAXIMUM HEIGHT OF THE WINDOW SILL IN BED ROOM #1 IS 44" ABOVE THE FLOOR. R310.1 STRUCTURAL PLANS: 1. FLOOR FRAMING / 5 ; PLEASE IDENTIFY THE 16" FLOOR JOISTS. 2. ROOF FRAMING / 5 ; THE RAFTERS OVER THE EXISTING PORCH ARE TO BE REMOVED. WHAT WILL REPLACE THEM? SECTIONS - DETAILS - MISC. NOTES: 1. 5 / 6 ; PLEASE SPECIFY THE JOIST HANGER ON THE DETAIL. THEY ARE LISTED IN LPI'S CATALOG BUT WHICH WOULD BE USED? SEE ELEVATION. 2. 6 / 6 ; ARE THE TOP AND BOTTOM CHORDS OF THE I-JOIST CUT? 3. 6 / 6 ; DESCRIBE THE FINISHED CEILING MATERIAL. PLUMBING PLANS: 1. PLUMBING NOTES / 13 ; PLEASE REFER TO ONE PLUMBING CODE. THEUPC APPEARS TO BE THE CHOSEN CODE. 2. COMBINATION WASTE AND VENTS ARE TO BE USED ONLY WHERE STRUCTURAL CONDITIONS PRECLUDE CONVENTIAL VENTING. UPC 910.1 PLEASE DIRECT HORIZONTAL DRAINS TO VENTS BEFORE THE FIXTURE TRAP. MECHANICAL PLANS: 1. MECHANICAL UPPER FLOOR / 11 ; THE CONDENSATE DRAINING INTO A VTR CONSTITUTES A WET VENTING BETWEEN DIFFERENT STORIES. UPC 908.1 HAVE YOU CONSIDERED THE TAIL PIECE OF A LAVATORY OR THE CLOTHES WASHER? ELECTRICAL PLANS: 1. RISER DIAGRAM / 12 ; T.E.P. REQUIRES A 2-1/2" RISER FOR 0 - 400 AMP SERVICES. TEP'S SR-310 2. THE 60 AMP SUB-PANEL REQUIRES A 30" WIDE X 36" DEEP X 6'6" WORKING SPACE IN FRONT OF THE PANEL. IRC FIGURE E3505.1 . TO WHICH SIDE OF THE WALL WILL THE SUB-PANEL OPEN? PLEASE INDICATE THE PANEL DOOR SWING. 3. PLEASE ADD A NOTE REGARDING THE LIGHT FIXTURE OVER THE SHOWER BEING REQUIRED TO BE LISTED AS APPROVED FOR USE IN WET AREAS. E3903.10 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 837-4910 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/24/2008 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 11/24/2008 | SUE REEVES | REJECT SHELF | Completed |