Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T08CM03317
Parcel: 113094650

Review Status: Active

Review Details: OTHER

Permit Number - T08CM03317
Review Name: OTHER
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
10/15/2008 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL


FROM: Michael St.Paul, Planning Technician

PROJECT:
T08CM03317
1218 East Glenn Street
Duplex


TRANSMITTAL: October 15, 2008


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1) This review is for a duplex with two bedrooms in each unit. The site is in the R-2 zone (LUC Section 2.3.5.2.A.2). The Development Designator is "K" (LUC Section 3.2.3.1.C) and the Perimeter Yard Indicator is BB (LUC Section 3.2.6.4). This site is also located on the Major Streets & Routes (MS&R) plan (LUC Section 2.8.3.1).

2) Dimension the roof overhangs. Where ever the roof overhangs exceed two (2) feet the setback is measured from the edge of the roof (LUC Section 3.2.2.6). Also identify the wall heights of the site plan.

3) The minimum setback along the interior lot lines is the greater of ten (10) feet or three-quarters the height of each wall of the structure facing the lot line. The wall heights for the second story are twenty-one (21) feet. The required setback is fifteen (15) and nine (9) inches to the south and east property lines (LUC Section 3.2.6.4). Only fourteen (14) is identified as the setback on the site plan. Correctly dimension the required setbacks and dimension the location of the building from each wall of the structure to the nearest property line.

4) Provide the sight-visibility-triangles (SVTs) on the site plan for the intersection and the proposed alley access (DS 2-02.2.1.A.10). Delineate and dimension both the sidewalks and the bike path on Mountain and Glenn. (I have provided street section and plan view drawings.)

5) Primary pedestrian and vehicle access must be provided to a public street. All vehicle access and parking is provided via the public alley to the south of the property (LUC Section 3.2.8.3).

Please be aware that additional comments may be required relative to changes made on subsequent submittals.