Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T08CM03315
Parcel: 133033080

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T08CM03315
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/30/2009 MARTIN BROWN FIRE REVIEW Approved
10/30/2009 MICHAEL ST. PAUL ZONING REVIEW Approved
11/05/2009 ANDREW CONNOR NPPO REVIEW Approved
11/05/2009 ANDREW CONNOR LANDSCAPE REVIEW Approved
11/05/2009 RONALD BROWN ZONING HC REVIEW Approved
11/25/2009 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond TO: Jeff Stanley PE
SUBJECT: New Single-Family Residence - Engineering Grading Plan 2ND Resubmittal Review
LOCATION: 1475 N Houghton Rd, (T08CM03315) Ward 2, T14S R15E Section2
PARCEL: 133-03-3080
REVIEWER: Elizabeth Leibold PE
ACTIVITY NUMBERS: T09BU00774, T08CM03315

SUMMARY: Engineering Division of Development Services Department has received and reviewed the Site and revised Grading Plan application for the above referenced property and recommends conditional approval with permit conditions. The overlay review T08SA00370 is a part of this project. The following comment 1 is required prior to picking up permits and the additional 6 comments apply to the grading permit.

SITE / GRADING PLAN CONDITION OF APPROVAL:
1) On Landscape Plan/NPPO sheet, assure floodplain information matches overlay, site and grading plan sheets.

SITE / GRADING PLAN CONDITIONS OF PERMITS:
THE FOLLOWING 6 CONDITONS APPLY TO THE GRADING PERMIT T09BU00774:
1) All future improvements (walls, fences, pool, and detached or attached accessory structures) will require separate permit for review and approval.
2) If grading construction is expected to last longer than the expiration date of the grading permit, contact DSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required.
3) The permitee shall notify the DSD when the grading operation is ready for final grading inspection. Final grading approval shall not be given until all work, including installation of all erosion control measures have been completed in accordance with the approved grading plan and grading permit.
4) Subject property is currently located within a Shaded Zone X 500-year floodplain as shown on the Flood Insurance Rate Map (FIRM), Community- Panel No. 040073-04019C-2257K, effective date July 24, 2000. A future 'A Zone' may apply after the next series of FIRM's expected in the Fall 2010. FEMA Flood Insurance may apply in the future.
5) Any construction for this lot after upcoming effective date of the expected future FIRM panel designation to Zone A may require a LOMR submittal and approval prior to approval of further permits.
6) If disturbance during construction exceeds approved limits, additional overlay and plan reviews may be required.

For resubmittal, please provide the 2 copies of the revised Landscape plans prior to picking up permits to assure correct floodplain data is labeled on Landscape plans. This may be done over the counter. I can be reached at 837-4934 if you have questions.

Elizabeth Leibold, PE
Civil Engineer
Engineering Division
Planning & Development Services Department
11/25/2009 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond LP/NPPO sheets revised to reflect 100-year floodplain limits per site and grading sheets.
12/01/2009 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved