| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/10/2008 | GERRY KOZIOL | WWM | REVIEW | Denied | needs 5th floor credit evaluation if applicable |
| 10/30/2008 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 11-04-08 Activity: T08CM03274 Address: 1240 E. Blacklidge Dr. Applicant: David S. Lutz Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. Any architect and/or engineer involved in the design of the structure shall seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. INCLUSIVE HOME DESIGN: 3. Remove the word 'unincorporated' from the Inclusive Home Design notes. 4. Thermostat controls must be within 48 inches of the floor but not less than 15 inches above the floor, 1003.9. FLOOR PLANS: 5. Clarify the square footage of the garage area. 6. Specify a 30" x 30" equipment working space for the water heater, M1305.1 7. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5/8" type X gypsum board or equivalent, and ½" gypsum board on supporting walls, R309.2. 8. Specify size and type of windows in master bedroom. 9. Specify tempered glass within 24" of doorways (bedroom 3) R308.4. STRUCTURAL PLANS: 10. Provide applicable cut references on framing plan for back porch. SECTIONS - DETAILS: 11. Ceiling gypsum board must be either 5/8" or ½" sag resistant when applied to ceilings framed at 24" o/c, IRC table R702.3.5 footnote d. PLUMBING PLAN: 12. Clarify size of water supply line from water meter. MECHANICAL PLAN: 13. Show supply and return air ducts with a minimum R-8 insulation, R1103.2.1. 14. Specify the size and location of combustion air vents for the mechanical closet, Chapter 17, 2006 IRC. ELECTRICAL PLAN: 15. Receptacles shall not be located below a counter where the countertop extends more than 6" beyond its support base, E3801.4.5 OUTDOOR LIGHTING CODE 16. Provide cut sheets for lighting fixtures on ceiling fans showing the angle of cutoff, or include in outdoor lighting calculation, Lighting Code 5.1.2. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/05/2008 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |