Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T08CM03172
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/03/2008 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS T08CM03172 Rev 12-5-08 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2006 International Residential Code, 2006 International Energy Conservation Code, and Arizona State amendments to the 2006 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or a finished reproducible set. Return two sets along with a set of the first submission for reference. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. (Do not cloud the changes made for comment revisions). Incorporate changes on originals and provide two copied sets for review. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2006 IRC with amendments on 6/12/2007, the 2006 UPC with amendments on 7/10/2007 and effective 1/1/2007 the Inclusive Home Design. All plans should reference these codes. Adopted amendments are found at: http://www.tucsonaz.gov/dsd/Codes___Ordinances/Building_Codes/building_codes.html FOUNDATION PLANS: 1. Show or note an 8" minimum separation of untreated exterior framing above finished grade for the Storage Building, R319.1 item 2. Add detail sheet 6. FLOOR PLANS: 1. Each detached (non-rated) structure requires a separate 3-foot fire separation distance. One structure requires not less than one-hour fire-resistive construction (without openings) if placed less than six feet from an existing building, R302.1. Show compliance with R302.1 (City of Tucson Amended) by providing a section detail of materials prescribed in IBC Table 720.1(2), Items 15-1.1 to 16-1.3. Add 1-hour rated detail sheet 6. STRUCTURAL PLANS: 1. Show all new exterior load-bearing walls on the Floor Plan and Framing Plan, R106.1.1. Show Framing Plan Keynote 7 for the new Dining wall between post and corner as load-bearing (Keynote 2 or 6). This is shown as a load-bearing wall with a header for a window opening. Add header notation. SECTIONS - DETAILS: 1. Clarify rafter sizes shown on Detail 1/2 consistent with Detail 1/3 and revise the insulation rating for a 5-1/2" cavity, R106.1.1. Reference fur-down note sheet 4 to three sections. PLUMBING PLANS: 1. Note the relocation of the Kitchen sink to comply with the 2006 UPC. If you have any questions please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |