Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T08CM03086
Parcel: 117081250

Address:
801 S MEYER AV

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T08CM03086
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/26/2008 GERRY KOZIOL WWM REVIEW Approved
10/10/2008 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Date: 10-14-08
Activity: T08CM03086
Address: 801 S. Meyer Ave.
Applicant: Robert Vint

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.
2. Any architect and/or engineer involved in the design of the structure shall seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

INCLUSIVE HOME DESIGN: (references taken from ANSI 117.1-1998 as amended)
3. Provide notes on plan to comply with the City of Tucson Inclusive Home Design.
4. Provide an accessible route from the public way extending throughout the entire first floor (except for exempt areas as defined in section 1003.3), 1003.2.
5. Vertical changes in floor elevation may not exceed ¼ inch (½ inch when beveled), 1003.4.
6. Thresholds may not exceed ½ inch in height, 404.2.5.
7. All door hardware must be lever-type or otherwise usable without tight grasping or twisting of the wrist, 404.2.7.
8. Door openings shall have a net width of not less than 30 inches, 1003.5.2.1.
9. Provide all switches, receptacles, and controls within 48 inches of the floor but not less than 15 inches above the floor, 1003.9.
10. Provide blocking in bathrooms for future installation of grab bars around: toilets, showers, and bathtubs, 1003.11.2.

FLOOR PLANS:
11. Specify safety glazing at hazardous locations, R308.4. (Breakfast area and bathrooms: within 24" of doorways; Adjacent to stairways and landings)

STRUCTURAL PLANS:
12. Correct section view references to front porch/balcony.
13. Provide consistent information on reinforcement in fireplace footing (Foundation plan does not agree with section view).
14. Provide engineer calculations for site wall exceeding six (6) feet in height (Detail 15 sheet A1.2).
15. Clarify sizes of 6x4 tube steel members on Framing plan sheet A3.2 (calculations based on TS 8x4¼)
16. Verify lintel in garage/courtyard wall (calculations based on ML-32).

PLUMBING PLAN:
17. Provide drainage system design for storm water accumulation in courtyard area.
18. Provide note requiring that water hammer arrestors be installed in accordance with ASSE 1010-2004 on water lines serving appliances equipped with quick-closing valves to include but not limited to: clothes washers, dishwashers, and refrigerators, UPC 609.10.

MECHANICAL PLAN:
19. Specify supply and return air ducts, which are outside the thermal envelope, are wrapped with a minimum R-8 insulation, R1103.2.1.
20. Provide a gas-fired appliance schedule, M1302.1.
21. Specify the diameter of the gas branch line to F-1.

ELECTRICAL PLAN:
22. Peninsula counter tops with a long dimension of 24" and a short dimension of 12" or greater shall have at least one receptacle, E3801.4.2.
23. Show receptacle outlets at wall spaces 2' or more so that no point along the wall (excluding door openings) is more than 6' from a receptacle outlet, E3801.2 (breakfast area).
24. Provide consistent over-current protection for panel B on panel A schedule.
25. Provide electrical service sized for the proposed demand per load calculations, E3502.2.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/15/2008 VFLORES1 OUT TO CUSTOMER Completed
10/15/2008 SUE REEVES REJECT SHELF Completed