Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T08CM02967
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/13/2009 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T08CM02967 1/14/09 127 S. CHERRY PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, IECC, AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2006 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FLOOR PLANS: 1. PLEASE PROVIDE A BRACED WALL PANEL AT THE NORTH END OF THE WEST WALL. R602.10.1 2. PROVIDE A DESCRIPTION OF AN ALTERNATE BRACED WALL PANEL FOR THE FIRST FLOOR OF THE TWO STORY ADDITION. R602.10..6 BOTH SIDES ARE SHEATHED. 3. PROVIDE A HAND RAIL FOR THE STAIRS. SECTIONS - DETAILS - MISC. NOTES: 1. B / 7 ; 3-16d PER STUD APPEARS TO BE INADEQUATE FOR A ROOF LEDGER CONNECTION. PLEASE JUSTIFY THE CONNECTION. ALSO, PLEASE PROVIDE A LEDGER CONNECTION FOR THE DECK. 2. K / 7 ; PLEASE SPECIFY MACHINE BOLTS VERSUS ANCHOR BOLTS FOR THE POST / BEAM CONNECTION. 3. K / 7 ; PLEASE PROVIDE A LEDGER CONNECTION. 4. K / 7 ; PLEASE DETAIL THE GUARD. 5. J / 7 ; PROVIDE THE SLOPE OF THE ROOF. R905.3.7 6. PROVIDE THE INSULATION R VALUE AND THE FENESTRATION U-VALUES. PLUMBING PLANS: 1. THE VERTICAL AND THE HORIZONTAL DRAIN FOR THE TWO LAVATORY SINKS IS REQUIRED TO BE NOT LESS THAN 2". UPC TABLE 7-5 . MECHANICAL PLANS: 1. PLEASE SIZE AND LOCATE THE RETURN AIR . 252 SQ.IN. MIN. ? IECC: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 837-4910 |
| 12/17/2008 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/15/2009 | CPIERCE1 | OUT TO CUSTOMER | Completed |